3. Insert the nozzle into the receiving tank and squeeze the handle to start fuel flow.
4. When done, release the nozzle handle.
5. Turn the pump off by pushing down on the power lever, and return the nozzle to its holder
(Fig. 4-29). Push in the master fuel pump disconnect to turn it off (Fig. 4-27).
I
CAUTION: Always store the nozzle in the holder. Do not
lay the nozzle in the bottom of the storage compartment
with the hose.
This pump is designed to be self-priming. If fuel is not delivered
within 15-20 seconds, turn the pump off and refer to priming
information in the Installation Section of the manufacturer's
owner's manual. An automatic bypass valve prevents pressure build
up when the pump is on with the nozzle closed. To avoid pump damage, do not run the pump more
than 10 minutes with the nozzle closed. After running the pump for a maximum of 30 minutes,
allow it to cool for 30 minutes.

MOTOR PROTECTOR

The motor protector trips automatically. This feature provides added protection against motor
damage and must be reset manually. When the motor protector trips, reset it by turning the switch to
OFF. Let the pump cool, then turn the motor ON again. If the motor protector trips again, see the
Troubleshooting Section of the owner's manual.