FURNACE

I
WARNING: This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. DO NOT try to light the burner by
hand.
The furnace requires both 12-volt and LP gas energy for full operation.
The combustion system is fully sealed. Oxygen is drawn from outside
through the center port of the vent by the fan motor. After burning fuel,
the carbon monoxide exhaust is expelled into open air through the outer
port of the vent. This vent is NOT to be altered or obstructed in any
manner to ensure your personal safety.
In order for the furnace to operate, a fully charged 12-volt battery or
120-volt power through the converter must be available. Listed below
are instructions for furnace operation. Additional instructions may be
found in manuals that are supplied by the manufacturers of the furnace.
Two types of thermostats are used. Thermostats are generally installed on an inner wall of a cabinet.
The thermostat in Fig. 5-1 is used for the furnace which DOES NOT have central air conditioning.
This type of furnace is D.S.I. (direct spark ignition) in operation and all functions will be performed
at the thermostat. The thermostat in Fig. 5-2 is used for the furnace with a central air conditioning
system. This type of furnace will operate by moving the switch to "heat" position on the system side
control. The furnace has it's own fan. No movement is needed on the "fan" side.

Operating Instructions

8. STOP! Read the safety information above.
9. Set the thermostat to lowest setting.
10. Turn off all electric power to the furnace.
11. This furnace is equipped with an ignition device which automatically lights the burner. DO
NOT try to light the burner by hand.
12. Open the furnace exterior door.
13. Turn the switch or circuit breaker to "OFF."
14. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you
smell gas, STOP! Follow "WHAT TO DO IF YOU SMELL GAS" at the beginning of this
chapter. If you do not smell gas, go to the next step.
15. Turn ON circuit breaker or switch.
16. Close the furnace exterior door.
17. Turn on all electric power to the furnace.
18. Set the thermostat to desired setting.
19. If the furnace will not operate, follow the instructions HOW TO TURN OFF ELECTRICAL
POWER TO FURNACE GAS VALVE and call an authorized Service Technician.

How to Turn off Electrical Power

1. Set the thermostat to lowest setting.
2. Open the furnace exterior door and turn OFF electric switch or circuit breaker.
3. Close the furnace exterior door.