4. MECHANICAL SYSTEM
4) Remove the screw, an remove the original
size sensor r; then, remove the flat cable
and all connectors to the IP PCB t.
4
Figure 4-511
5) Remove the four screws, and remove the PI
PCB.
4–30
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
D. Laser Scanner Assembly
1. Removing the Scanner Cooling
1) Remove the four screws, and remove the rear
5
2) Remove the scanner cooling fan.
3) Remove the three screws, and remove the fly-
4) Remove the cable guide by disengaging the
5) Remove the two screws w, and remove the
2. Removing the Laser Scanner Unit
1) Remove the rear cover, and remove the scan-
2) Remove the copyboard glass, CCD unit cover,
3) Remove the fan duct 2 q by sliding it to the
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
Fan Duct 1
cover.
wheel.
hook assembly.
scanner cooing fan duct 1 q by sliding it to
the left.
1
2
Figure 4-512
ner cooling fan duct.
IP cover, and IP PCB.
rear.
2