Feeding Assembly - Canon GP200 Service Manual

Hide thumbs Also See for GP200:
Table of Contents

Advertisement

3. Removing the Separation Pad
1) Remove the right door.
2) Remove the multifeeder pick-up roller.
3) While pushing the end q of the right door in
the direction of A, remove the rear of the sep-
aration pad cover w in the direction of B.
Figure 4-411
4) Remove the separation pad retaining plate e
by releasing the hook r.
Figure 4-412
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
B
2
1
3
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
C. Feeding Assembly
1. Removing the Feeding Assembly
1) Open the front door, and remove the fixing
inside cover; then, remove the fixing unit. (4
connectors, 1 screw, 1 grounding screw)
2) Remove the drum unit.
3) Disconnect the connector q, and remove the
grounding screw w.
4) Remove the screw, and remove the feeding
assembly positioning pin e; then, remove the
feeding assembly r from the front.
A
1
4
4. MECHANICAL SYSTEM
2
3
Figure 4-413
4
4–21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp215

Table of Contents