Canon GP200 Service Manual page 174

Hide thumbs Also See for GP200:
Table of Contents

Advertisement

3. OPERATIONS AND TIMING
Control r
1st to 30th copy
31st to 40th copy
41st to 50th copy
51st to 100th copy
Control t
1st to 40th copy
41st to 50th copy
51st to 100th copy
b. If the temperature is 100°C or more or less
than 140°C at copy start, one of further three
types of control is chosen depending on the
count of copies: q 215° through 180°C, w
205° through 180°C, and e 195° through
180°C:
Control q
1st to 5h copy
6th to 10th copy
11th to 15th copy
16th to 20th copy
21st to 30th copy
31st to 40th copy
41st to 50th copy
51st to 100th copy
Control w
1st to 15th copy
16th to 20th copy
21st to 30th copy
31st to 40th copy
41st to 50th copy
51st to 100th copy
Control e
1st to 30th copy
31st to 40th copy
41st to 50th copy
51st to 100th copy
3–120
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
205°C
200°C
190°C
180°C
195°C
190°C
180°C
215°C
210°C
205°C
200°C
195°C
190°C
185°C
180°C
205°C
200°C
195°C
190°C
185°C
180°C
195°C
190°C
185°C
180°C
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
c. If the temperature is 140°C or more at copy
start, control is exerted so that the tempera-
ture will be 180°C at all times.
1st to 100th
Note that, a (less than 100°C at copy start)
and c (100°C or more and less than 140°C) are
always combined as follows; the notation "value
on label" here refers to the label attached to the
fixing assembly, and the settings recorded on the
label may be entered in 'FILM LAMK' in service
mode (*3*) to select a specific fixing control tem-
perature.
Value on label
a
q
0
w
1
e
2
r
3
t
4
Reference:
Normally, 1, 2, or 3 is selected. Select a
higher temperature (lower value) in service
mode if fixing faults occur; select a lower
temperature (higher value) if offset occurs.
For instance, if fixing faults occur with 2
selected, change it to 1 or 0. Try 1 first and
then try 0 if necessary.
If offset occurs with 2 selected, change it to
3; if offset continues, change it to 4.
180°C
b
q
q
w
e
e

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gp215

Table of Contents