4. PD Density Auto Correction
This mode must be executed in combination with 200PWM density auto correction and 600PWM den-
sity auto correction.
Item
PD density auto correction
COPYRIGHT © 1996 CANON INC.
Download service manual and resetter printer at http://printer1.blogspot.com
*4* FUNCTION 04 – > ( )
PD PRINT (START)
WHITE MEASURE (OK)
DENSITY SAMPLING (OK)
DATA SET
A=+xxx, B=+xxx, D=+xxx
xx xx xx xx xx xx xx
xx xx xx xx xx xx xx
MULTI
0
>CASSETTE1
A4 1
CASSETTE 2
A4 1
+
1) Press 'PD PRINT' to highlight; then, press the
Copy Start key.
• A 15-gradation test pattern will be generated.
2) Place a blank sheet of paper (the whitest of all
used by the user; no color copier paper allowed)
on the copyboard glass; then, press 'WHITE
MEASURE' to highlight, and press the OK key.
• The scanner makes a single scan.
3) Replace the paper with the test pattern generated
previously; then, press 'DESNITY MEASURE' to
highlight, and press the OK key.
Printed side down
4) Check the values under A, B, and D:
20≤A≤50
–40≤B≤40
0≤D≤8
5) If the values are as indicated, press 'DAT SET' to
highlight, and press the OK key.
CANON GP215/200 REV.0 JULY 1996 PRINTED IN JAPAN (IMPRIME AU JAPON)
3. OPERATIONS AND TIMING
CANCEL
JUMP
OK
Description
Reference
page
Service
handbook
p.2-21
3–211

Hide quick links: