Wireless Specifications

Zone Transceiver II Specifications
ITEM
• ZT II U
Output Power
Type of Interface
Number of Simultaneous Speech Path
Power Supply
Power Consumption
Operating Conditions
Dimensions (unit: mm)
Weight
Wire Diameter
2W
PBX Power
Supply at -48 V
4W
2W
PBX Power
Supply at -45 V
4W
2W
PBX Power
Supply at -43 V
4W
Local Power Supply
System Capacity
Description
Zone Transceiver (ZT)
Dterm PS
Note
CSI
4CSIA-A
CSH
PS Simultaneous Connections
Calling Area
ZT per Calling Area
Note: All existing CSH cards in a system should be SPN-SC03B 8CSH-C (AP) when accommodating
257 or more PSs.
UNIVERGE
2000 IPS Request For Proposal (RFP) Reference Guide
NEAX
Issue 6
6.8 mW
U Interface
Maximum 3
• PBX Power Supply (DC –48 V)
• Local Power Supply (AC 100 V/200 V)
Maximum 3 W
Ambient Temperature: –10 50 °C
Relative Humidity : 45 - 85 % (non-condensing)
Installation Location : Indoor
160 (W) x 1 39 (D) x 4 0 (H) (Excluding Antenna)
Approx. 400 g
26 AWG
24 AWG
2500 ft.
4000 ft.
(762 m)
(1219 m)
4300 ft.
6900 ft.
(1310 m)
(2103 m)
2000 ft.
3200 ft.
(609 m)
(975 m)
3500 ft.
5600 ft.
(1066 m)
(1706 m)
1800 ft.
2900 ft.
(548 m)
(883 m)
3100 ft.
5000ft.
(944 m)
(1524 m)
11000 ft.
13000 ft.
(3350 m)
(3958 m)
Integrated
1PIM 2PIM
16
32
SPECIFICATIONS
22 AWG
19AWG
5500 ft.
8000 ft.
(1676 m)
(2438 m)
9500 ft.
13000 ft.
(2895 m)
(3958 m)
4700 ft.
7000 ft.
(1432 m)
(2131 m)
8200 ft.
12200 ft.
(2499 m)
(3718 m)
4400 ft.
6400 ft.
(1340 m)
(1948 m)
7600 ft.
11000 ft.
(2316 m)
(3352 m)
13000 ft.
13000 ft.
(3958 m)
(3958 m)
Capacity
Adjunct (Analog) Adjunct (CCIS)
3PIM
4PIM
5PIM
48
64
80
512
32
24
216
32
128
Chapter 16 Wireless System
6PIM
7PIM
8PIM
96
112
128
Page 16-15