Chapter 11 Open Application Interface

OpenWorX: Multiple CCIS Node Configuration

OpenWorX is capable of hosting applications for multiple
on a single server.
OpenWorX server and the
previously in this chapter to make sure your connection is sufficient.
The applications once equipped with the remote TCP/IP connection and multi-node software
operate as if they are in a single
BAS: CCIS Network Information
The Business Attendant System can run in a CCIS network environment with the following limitations.
Calls transferred from the BAS Client across a CCIS Link will not recall to the BAS operator.
Using multi-node capabilities, the operator can now view station data via the directory or speed
dials to extensions in other IPS systems. The other IPS systems must have OAI and a TCP/IP
connection back to the OpenWorX server. Additional OpenWorX software is also required per
IPS to be added on the server.
Business Receptionist: CCIS Network Information
The Business Receptionist can run in a CCIS network environment with the following limitations
Calls transferred from the Business Receptionist across a CCIS Link will not recall to the
operator.
The Dterm across a CCIS Link cannot be monitored by the Business Receptionist system and
the monitored speed dials and status checks in the directory will not function for those
extensions.
The system will force supervised transfers to CCIS extensions to ensure callers do not get
transferred to a busy remote extension.
The message-waiting lamp cannot be controlled on a remote Dterm.
Note: Business Receptionist does not have the same multi-node capability that BAS does

OAI Application Software Development

For users wishing to develop their own applications, NEC offers a complete library of
development tools. For further information, contact the OAI Product Manager.

System Specifications

Required Equipment for OAI
Equipment
PN-CP24-C (MP)
PZ-M606-A (ETHER)
• 10BASE-T Cable
• 100BASE-TX Cable
UNIVERGE
2000 IPS Request for Proposal (RFP) Reference Guide
NEAX
Issue 6
All instances of this require a viable OAI connection between the
U
NIVERGE
NEAX
U
NIVERGE
Description
MP Card
Ethernet Control Card
10BASE-T/100BASE-TX
Cable between Ethernet
Card and LAN
U
NIVERGE
2000 IPS. See the bandwidth requirements list
2000 IPS, except where noted below.
NEAX
Qty
1
One card per system Mount on
PIM0
1
Mount on MP card One card per
MP
As
Cable length:
required
Maximum 100 m (328 ft.)
2000 IPS systems
NEAX
.
Remarks