Table 2: Description on error codes
Code
A
01h
DECODE_ERROR
02h
RF_NOT_EXIST,
03h
RMD_NOT_DETECT,
04h
LIN_NOT_DETECT,
05h
LIN_NOT_COMPLETE,
06h
ILLEGALL_NUMBER_OF_BYTE,
07h
IF_ABORT_DET,
08h
MECHA_TIMEOUT,
09h
BUFFERING_TIMEOUT,
0Ah
RETRY_TIMEOVER,
B
0Bh
READ_TIMEOUT,
0Ch
RECOVERED_DATA,
0Dh
VERIFY_ERROR,
10h
M63_INTERNAL_ERR
11h
M63_FORMATTER_ERR,
12h
M63_IDOVER_ERR,
13h
M63_HDCMP_ERR,
14h
M63_UNCORRECTABLE_ERR,
15h
M63_CRC_ERR,
16h
M63_ETC_ERR,
17h
M63_BLK_ERR,
C
18h
M63_HDC2_ERR,
19h
Internal Timeout
1Ah
M63_TRX_ERR
1Bh
Mecha Not Active
1Ch
FIFO Error
1Dh
Buffering Abort
1Eh
Too Far From Target ID
1Fh
M63 Replay Req.
20h
Buffer Full
21h
Buffer Under Run
D
22h
Panic in
23h
Discontinuous time data
24h
Wobble servo phase difference exceeded
25h
ASYOVR allowable count number exceeded
26h
ASYNC allowable interpolation number exceeded
27h
Invalid Cue Sheet
28h
Non Cue Sheet
29h
Disc Full
2Ah
Reserved Track Full
E
F
136
1
2
Content
PRV-LX10
2
3
Supplementary information
Failure in reading PreGap (CD), improper results of RFEndSeek (DVD)
Read-request address not recorded
RMD not detected
Lead-in not detected
Incomplete lead-in
Illegal CD mode detected (Illegal Mode for This Track Error)
Processing aborted upon the request of I/F
Timeout waiting for search
Combo Chip decoding not started (the screen is frozen but remains active)
Number of times of retrial over
Timeout waiting for read process
"Recovered error" detected
An error was generated while the Verify command was being processed
Failure in internal processing
Failure in detecting a sync
Target-ID exceeded
Header-compare error
Unrecoverable error
CRC error
Other errors of Combo Chip
CIRC unrecoverable error
Header C2 error
Timeout waiting for Combo Chip internal processing
Failure in transmitting data to the host computer
Mechanical-control computer not ready for search (tray opened, etc.)
Internal FIFO error
Failure in obtaining DVD-data-type information
Improper address after search (too far before the target address)
Combo-Chip decoding not started (the unit arbitrarily returns to idling status)
3