• Level 3 (Level 2 on the Function Menu): Warning symptoms of an HDD failure
A
As this level may have resulted from a temporary cause, it is defined as a level that requires careful use of the HDD as per
the instruction manual. The cause may not be a problem if the user does not recognize any symptom. Thus, even if the
result level is 3, it does not mean that replacement of the HDD is necessary. However, it is not recommended that the user
continue using the unit as is. Therefore, if servicing is requested by the user, even if the request for servicing is for another
reason, replacement of the HDD should be also performed. In such a case, check if the HDD has been exposed to any
inappropriate environment, such as extreme temperature, vibration, noise, or temporary blackout, on the user's side.
Especially, check if the user turns off the power in a correct way. If user's handling of the HDD is inappropriate, he/she must
be instructed on appropriate handling of the HDD.
• Level 4 (Level 3 on the Function Menu): On the brink of an HDD failure
• Level 5 (Level 4 on the Function Menu): HDD failure
B
Replace the HDD. If failures of these levels occurred several times within 2 years after installation, it is likely that the HDD
has suffered from mishandling by the user. If it is the case, the user must be instructed on appropriate handling of the HDD.