Fililing The System - Worcester Greenstar 12i System Instruction Manual

Wall hung rsf gas fired condensing boiler
Hide thumbs Also See for Greenstar 12i System:
Table of Contents

Advertisement

SYSTEM FILL
Heating
return
Stop
cock
~ORCESTER
Bosdl
Gt0t1p
Non
retum
valve
~
Non return
valve
~
....
Temporary
hose
Test cock
Mains
supply
Stopcock
..
------
ltfST.........,()N 6
SEIMCING 11-iSTRVCTlON
S
!<OR WORCESTER
GAttNStNI 121
S,~
Sf$tcll
8716 112055a(C410G}
\
\
I
I
I
I
FIWNG
THE SYSTEM
1
Tum on
the
water
main and open
the
system
valves.
2
Open
all
radiator
valves.
3
Fill
the
system
via
a
WRAS approved
mting
loop.
4
Vent {A)
arrt
air
from
the
boi:ler heat
exchanger
usrng
a
suitab'e
conteiner to
coiJect any
water.
Ensure
tube
outlet
(B)
is
directed
away
from the
fan
or
any
other
electrical c:omponent to prevent any water
damage.
Also
place a suitable cover
over
the
fan
to
prevent
any spillage
of
water
on
to
electrical connections.
Ensure
the
cover
Is
re-moved
afte-r venting,
5
\lant
all
radiators.. re-tighten
when
oompJeted
and
check
the
system and correct
any leaks.
The
boiler integral expansion
vessel
is
pre~
ch~ged
to
0
.
75
bar (equal to ;)
static
he(ld
of
7.5m
(2211). A Schraedet
type valve is
fined
to the expansion vessel to
allow
for
pressure
adjustment
tf
required.
If
an extra expansion
ves-sel
is- fitted
to the
central heating
retum
1
adjust this to the
same
pressure
as
the
tJpp/iance interntJI
expansion
vessel,
refer
to separate
instruc·
lion$ with
the
extra expaMion ves$el.
6
Briefly open
the
pressure
refief vatve to
test
its
operation.
7
If
requited increase
system pressure
back to
1
bar.
8
Rotate
the
adjustable poinler
on the
pressure
gauge
to
reeotd the set system
pressure.
9
Isolate and
remove
filling
loop connection to
system.
FILliNG
THE SYSTEM