Fault Finding & Diagnosis; Fault Finding - Worcester Greenstar 12i System Instruction Manual

Wall hung rsf gas fired condensing boiler
Hide thumbs Also See for Greenstar 12i System:
Table of Contents

Advertisement

FAULT
FINDING
NOTE :
This
fault finding information is
for
guidance
only.
Worcester cannot be held responsible
for
costs
incurred
by persons not
deemed
to be
competent.
The
electronic
control
system for
this boiler
incorporates
a blue
central
indicator. This
normally
confirms the
permanent
mains
supply
but,
by
flashing
at different rates during a
fault,
provides a guide
to
the
cause as
listed.
This
fault
finding
system
assumes
that the
appliance
has
been
operating
normally until
the
time
of
failure (i.e.
not
a
first installation error).
PREUMI
NARY CHECKS
:Preliminary
elec1rical
system
checks
are
the
first
electrical checks to be
carried
out
during
a
fault-finding
procedure. On
oompletion
of
the Service/Fault-Finding
task
which
has
required
the
breaking and remaking
of electrical
connections, check
(a)
EARTH
CONTINUITY,
(b) SHORT CIRCUIT
CHECK,
(c)
POLARITY
and (d)
RESISTANCE
TO
EARTH.
Blue
light
Lockout reset
Fault
Possible solution/check
indication
button
Off
Off
No power
at
control
board
PE!rmanent
mains supply
to
boiler.
Boiler
mains sw
itch.
Fuse F1, 2.5A
or
Fuse F3,
0.5A
Tt3nsformer
(both
coils
below
100Q).
Otherwise
replace
control board.
On
Off
Boiler
not
operati()Q
during
External
dfvetter
valve.
central
heating
dem&nd
External
timer
or
room
stat
(HWok)
OR
If
optional
diverter valve
is fitted:
Temperature
control
in
frost
protection
position.
Live
demand
at
ST1o-LR (extemal
CH
demand).
Facia mounted timer
(if
fitted).
Diverter
v;J.Ive.
Control
boerd.
Boiler operating
Some older
thermos
tats
(contair\ing capacitors) may
give a
low
without live
dQmand
at
voltage
retum
at
ST
10·LR
when the themlostat contacts are
open.
ST1
0-l.R (from external
Check tha.t
there
fa
not a permanent live at ST10·LRfrom
another
roomsta.t
timer).
$0UfC9.
Boiler not
opecating during
ExternaJ
diverter
valve.
hot
watar
demand
(CH
ok).
External
timer or cylinder s
tat
OR
If
optional
d
lverter
valve
ls
fitted:
Short circuit
acrosa
ST8
from
cylinder
s
taVtimer.
Facia mounted timer
(if fitted).
Oiverter
valve.
Contro
l
board.
Boiler
not
opBrating during
Temperature
control
in
fros
t
protection
position.
any demand.
Live
demar\d
at ST10.LR
{from extemal
system).
Control
board.
OR
If optional diverter valve
Is
fitted:
Timer.
Control board.
S low
flash
Flashing (reset
r&quired)
Ignition
lockout
Gas
present and
at
correct
pressure.
(normally
off,
Combustion
co
2
level.
Flue
condition.
flashes on)
Ignition electrodes
I
harness
I
connections.
Gas valve
(coils
140
·
1900)
/ low
voltage harness
connection.
Otherwise
replace C()(ltrol
board
.
S
low
flash
Flashing
(reset requi-red)
A ue
Ov9Iheat
Heat
exchanger
blocked.
(normally on,
Heat
cxchangCI
baffle$
removed
and
not refitted.
flashes
oH)
Heat exchanger
overheat
Water pressure.
All air
vented.
Pump
I
harne$S
I
connections.
Water leak&
I
blockages.
Safety
thermostats /low
voltage
wiring
harness
I
connections.
Otherwise
reoJa.ce control
board.
Rue
blockage
Blockage
in
flue system.
Fast flash
Off
VotatiJe lookout
Temperature
sensor
{8000·20,0000).
Low vohage wiring harness
I
COMections
to senSOt.
Fan
I
fan
hamess
I
connections to
tao.
Code plug
fitted.
Fast flash
Ftashina
Internal
fault
Replace oontrol
boerd
2
pulses
No
r
~ght
Not a fault
code
SeMoe
mode
selected
to
min,
press
service button to
retum
to
normal.
5
pulses
No
light
1
Not a taun
code
Servioe mode selected
to
max,
press
service
button to
retum to
normaJ.