IHGT"IUAflON 6
SEIMONG
INSTRVCTlONS FOR
WORCESTER GRttNStNI Ill
5,~
S,'llcll
87161 12055a(C4105}
FLUE
INSTALLATION
MEASURING
THE
FLUE
(Ext011sion
Flue
Kits):
ONLY CUT EXTENDED FLUE LENGTHS
•
As
w
ith
the
S
tandard
Flue measure
from
t
he
outside wall
to
the
centre
line
of the
H
ue
turret.
•
Subtract
the length
of
the
Standard Flue
and turret
(725mm} from
length
l
.
•
Subtracc
the
full
length 1m extension(s)
from
the
figure.
•
Cut
one
of
the 1m
extensions
to the
remrundor.
•
Cut
both
tubes
squate
taking
care
not
to
distort
tM
rubos.
•
R9m0Yeany
burrS.
EXAMPlE:
L.eng1h
l
-
Sublroct
Standard
Flue+
Tune!
Subtract
Fu1
Exteooion
Cut
l
ength
=
2380nm
-
686mm
-9eomm
734mm
NOTE:
The
minimt.m
length
a
flue
extension
can
be
cut
to
is
100mm
NOTE:
Where
extensions are
reduced,
cut
length which
DOES NOT
contain
t
he seal.
ADDITION
OF
FLUE
BENDS:
When flue
bends
are being
used
an
elfowanoe
of
98mm
per
beOO
must
be
allowed from
the
centre
line
of
the bend.ln the
example
shown
using
a
flue
extension
with
2
bends
will
achieve a
total
length
ot
1148mm
.
FLUE
INSTALLATION