Boiler Location & Clearances 13·14 - Worcester Greenstar 12i System Instruction Manual

Wall hung rsf gas fired condensing boiler
Hide thumbs Also See for Greenstar 12i System:
Table of Contents

Advertisement

SERVICING CLEARANCES
VENTED COMPARTMENT
Using
1
OOmm
fl:ue
kit
1060mm
Using
125mm
flue
kit
1110mm
930mm
20mm
, to
removable door
'600mm
,
front
cfe~r.mce
,
for service
VENTILATION FREE COMPARTMENTS
INSTALLATION CLEARANCES
4
10mm
+
'
'
Smm
200mm
Ventilation Free Compartment Installation Clearances
The
suggested total
unventllated
compartment minimum clearances
a.re:
Side
Above
Below
Front
(to removable
door)
400mm
170mm
approx.
20omm
10omm
(30mmabove
the
elbow)
(Note:
Top and
bottom
clearances
must not
be reduced below these values
as
they are the
m inimum
required
for
servicing).
If
Side Clearances are Reduced
If
total
side
cl
earance Is
Then
overall
height
dearances
Ffont
dun~nce
<to
r•
movabl•
reduced to:
must be Increased to
(a,Pprox):
OR
door)
must
be i ACteased
to:
••
35omm
441mm
129mm
300mm
523mm
161mm
250mm
617mm
-
20Qmm
200mm
727mm
243mm
150mm
856mm
i
I
II
295mm
100mm
1012mm
358mm
50mm
1202mm
II
434mm
If
Front Clearance is Reduced
If
front
c:IQrance
(
to
Then
ovo~ll
height
d
aran"s
Total
side clearance must be
removabJe
door)
Is
must
be
increased to
(epprox):
OR
incrused
to:
reduced to:
••
SOmm
511mm
506mm
25mm
596mm
569mm
BOILER LOCATION
&
CLEARANCES
This
boiler
is onty
suitable
foc
installing internally
within
a
property at a suitable
~atOO
onto
a
fixed, rigid
surface at
least
the same
size
as the
boiler
and
capable
of
aupporting the boiler
weight.
COMPARTMENTS:
Follow the requirements of
B$6798
and
B$5440
Part
2
and
note:
Minimum
clearances must
be
maintained
All
access
door
is required
to
iM
t
aJJ,
seMce
~nd
maintain
the
boiler
and any ancil!iary
equip ment.
• If
fitting
the
boiler
into an
airing
cupboard
use
a noll-combustible perforated
material
(max:imum hole
sizea
of 13mm)
to
separate
the boiler
from
the airing
space.
BOILER
CLEARANCES:
The diagram opposite
shows
the
minimum
space
r&qui:red
to install
and
service
the
boiler.
If
a
boiler
is
installed
in
a compartment with
clearances less
than
shown in the
tables oppo-
site,
ventilatOO
is
required.
Refer
to
tables
below
for
ventilation
requirements.
12 & 24 kW
Vent
To
room
or
Direct to
position
Internal
space
outside
Hjgh
Minimum
free
M'mimum
level
area
122
cm'
free area
61
em'
low
Minimum
frae
Minimum
level
area
122
cm'
free
area
61cm
1
BOILER CLEARANCES· UNVENTILATED
COMPARTMENTS:
The tables
opposite
s
how
the options
for
the
mi:nimum
space required
to i:nstall and
service
the
boiler
inside
an unventilated
compartment.
"'NOTE:
These
are
the combined
top & bottom
clearances excluding the appliance.
••NOTE:
These are
the
combined
left
&
Aght
clearances
excluding
the appliance.
BOILER
LOCATION
& CLEARANCES
INSW.LNlON
&
SERVICI~ IHSfRUCf~Ct>:S
FOA
WORC~
GREENSfAA 121
S,lk!fl'l/24! Sp
kM
811G 112
Cl!ll!ol
(OVOO)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 24i system

Table of Contents