Flue Options - Worcester Greenstar 12i System Instruction Manual

Wall hung rsf gas fired condensing boiler
Hide thumbs Also See for Greenstar 12i System:
Table of Contents

Advertisement

STANDARD FLUE
HORIZONTAL
./S,)CJ
Cl =:::OlPP
A
0100
MAX
686 Ax
1
MIN
260 Ax
I '
0125
MAX 1070 A
X
1
MIN
250 Ax
1•
Requires cutting
MAXIMUM FLUE
HORIZ
ONTAL
_Qt:J
!
IP
A
0100
4600mm
Ax
1
+Bx5
0125
13000mm
Ax1+Bx 13
B
~----·······
...
···········-~
'
MAXIMUM
FLUE
VERTICAL START+
1
BEND
c
O
0100 • 4600mm
Ax
1+
Cxl+Bx5+
F
x
I
0125
·
13000mm
Ax
1 +
Cxt
+
Bx
13
+
Fx
1
.•........
-·············..!
/·····
MAXIMUM FLUE HORIZONTAL+
1
BEND
0100
2600mm
Ax
1
+
Bx3+Cx1
0126
·
IIOOOmm
Ax1+
Bxli+Cx
l
FLUE
OPTIONS
MAXIMUM FLUE VERTICAL
START+ 2 BENDS
A
F Q
I
II?
B
cO
0100
·
2600mm
Al(
1
+Cx2+
Bx4
+
F
x
1
0125
·
IIOOOmm
A
X
1
+
C
X
2
+
8
X
13
+
F
x
1
MAXIMUM
FLUE
VERnCAL
START
+ 3 BENDS
0100
·
NIA
0125
·
9000mm
Ax
1
+
Cx3+ Bx11
+
Fx
1
MAXIMUM FLUE VERnCAL
WITH
2
x
45' BENDS
Ebi.
B
D(/
0100
·
4400mm
{including terminal)
Bx5+ Dx2
+
Ex
1
~
0125
·
13000mm
"'-
.-?
(including terminal)
Bx13+
OX2
+Ex1
VERTICAL FLUE W
ITH
2
X
90'
BENDS
E
Q
B
co
0 100
·
2400mm
(including terminal)
B
x
4+
Cx2+Ex
1
0125
· IIOOOmm
(mcluding
terminal)
Bx 13+ Cx2+
Ex 1
·-
0--
h
'-.
""
FLUE
OPTIONS
Th&
d
i.agr~ma
(opposite}
show
the
components
used
and
tho
maximum
flue
length fOI each
configuration
of
100mm
and
125mm flues.
Shaded flue c:omponents
indicate
the
standard 100mm
horizontal
ftue.
Only sttaight
flue
sections can
be
reduced in
length
and
cut.
The flue
terminal end
can be
fitted
from the
ir\&ide or outside
of
tha building.
Faing kits
am
supplied
with
the
flue
extension
lOis.
Horizontal
125mm
and
Vertical
100
mm
and
125mm flue kits
are
available
with separate
in$tructions.
Contact
your supptier or
Worcester.
A
Standard horizontal
flue
(100mm
diameter
shown)
B
·
Straight flue
extension
C
Rue
bend 900
0 ·
A
ue
bend,
45°
E
Vertical terminal
(vertical
adaptor
supplied
with
terminal)
F ·
Vertical
adaptor
(usad
with
horizontal
terminaO
Galoulating th&
flu&
length:
Measure the
total
flue
length
required,
noting
that
the
maximum
stiaight flue
lengtb including
the
terminal
is:
Horizontal60/100mm: 4600mm
Hocizontai
801125mm:
1
3000mm
Vecticat
601100mm:
6400mm
Vertical80/125mm:
15000nwn
Then reduce
the
total
straight flue length
fOr
each extra
flue b1M1d
(excluding
the
flue
elbow)
by:
2000mm
for
90°
lOOOmm
fOC"
45°
Flue
Extension
lengths:
Hocizontat &
Vertical
60/lOOmm:
960mm
Horizontal
&
Vertical
801125mm:
1000mm
Flue
Terminal
lengths:
Horizontat
60/100mm: 800mm
ind...::i-lg
tooninal
Horizontal 801125mm:
1200mm
Vetticaf 601100mm:
1140mm
to
top of terminal
Vertical801125mm:
1365mm to
top
of terminal
INSW.VIlON
&
SERVICING
lhSfiWCfltNS FOA
WORC~
GREENSfAA
\
21
&,l~
SpkM
8
71
G
1120!!6.l(~
;WORCESTER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 24i system

Table of Contents