PRESSURE RELIEF PIPEWORK
PRESSURE
RELIEF
PIPEWORK:
IMPORTANT: The pressure
relief
valve
is a safety device for the
boiler
and
rt
activated may discharge boiling water
steam through the
relief
valve
drain
pipe.
Care should
be
taken when siiing the
outlet
pipe
so that
jt
does not c:ause an
obstruction or
discharge above a
window.
entrance or other public access
where
It
could
cause a hazard.
The
pressure
relief
drain
pipe (M)
from
the
boil
e r
should
be
at least
16mm
diameter
c:opper
pipe
and run
downwards away
from
any electrics or
other hazard,
preferably
to
an
external
drain
or soakaway.
P;pe
(M)
should
be
fin;,hed
with s
port;sl
bend,
near
the outfet to
face the
extetnal
wall
(as shown)
to help
prevent
hazard.
L
Outside wan
O,M
• Drain
pipe
N
Ext&rnal drain
PRESSURE RELIEF PtPEWORK