Worcester Greenstar 12i System Instruction Manual page 74

Wall hung rsf gas fired condensing boiler
Hide thumbs Also See for Greenstar 12i System:
Table of Contents

Advertisement

If In the unlikely event the boiler does not give
complete
sati sfaction,
before
calling for a
service
engineer,
the
installer
should
check
the
following:·
For boilers with external diverter
valves and
controls
No Central
Heatjng
but Hot
Water OK
Unlikely
10
be
a
boiler fau", please ask your eleclrician lo
chock
lhe
external
conl
rols.
No
Hot
Water
but
Central
Heating OK
Unlikely to
be
a boiler
fault, please
ask
your
electrician
to
check
the
external
conlrols.
Ng
HW
gr
CH demand
Is !here
a
demand !Tom external
conlrols?
To
eliminale
the
boiler
u a
fault,
remove
the
switched
rove
!Tom lhe
wiring
oenlre to LR
on ST
1
0, then fit
a
link
betweeo
the
La and
LR.
If the boiler and pump
run
normally theo
it
is likely
there
ia a
fault with lhe external contrOls.
Please
contact
yOU<
electrician.
For
boilers
with internal diverter valve and
controls
No
Central
Heating
but
Hgt
Water
OK
Remove the
room
stat
wiring
from
Ls,
LR
and N
on
terminal
block STt
0.
Frt
a
link
between
Ls
and
LR, if the
CH
now
works there
is
likely
to
be a
problem
with
tho room s
tat or wiring
to
it.
No
Hot
Walle
b
ut
Contcal
Heating
OK
Remove
the cylinder
stat
wiring
from
8 and
10
on
the
terminal block ST8. Fit
link
across
8
and 10.
For all
boilers
with Internal or external
controls
Burnec
lights
!bon goes out
jn
DHW or CH
mode
Does the
boiler
run nonnally
with
the
front cover
oil and then
tall
When
the
cover
Is
put back on?
H yes there
ia
likely to
be
a flue problem • eitller lhe air inlet
ia
blocked
or the
inner flue
is
leaking fuo gases
into
lhe
u
inlet.
Bollec
nglsy
or
gglng to overheat
1.
Was the
system flushed?
2.
Has
tho
pump been
bled
and
the
dust
cap
released.
General checks
1
.
Is
all
the air bled from
the gas supply?
2.
Is
all
the
air bled
from
the
primary water
system?
3.
ls
there
230v ac across
the
boiler
live
and neutral
terminals?
(l&NonST10)
4.
Is
the polarity correct?
5.
Is the incoming gas pre....-e at
least 18mbar with the boiler at mwnum
output?
EXCELLENCE
COMES AS STANDARD
Worcoatar, Boech
Group
Cotswold
Way,
Warndon,
Worcester
WR4
9f'N'/.
Tel.
01905
754624 Fax.
Ot
905
7546t
9
Worcester,
Boech
Group
is a
trading
name
of BBT
Thetmotedmology UK
Ltd.
www.wor<:esler·bosch.co.uk
I 711
112
OOSI04/0l)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 24i system

Table of Contents