Chapter 9 Operation and Maintenance

9.2.2 Error Messages

This section explains the error messages for this server.
■ POST Error Messages
This section explains error messages of POST (Power On Self Test: a device check performed during the
server startup).
If an error occurs during POST, the following messages are displayed.
Failure Fixed Disk
Stuck Key
Keyboard error
Keyboard controller error
System RAM Failed at offset: nnnnnnnnh
Shadow RAM Failed at offset: nnnnnnnnh
Extended RAM Failed at address line: nnnnh
Memory type mixing detected.
Memory decreased in Size
Non Fujitsu Siemens Memory Module
detected - Warranty restricted!
System battery is dead - Replace and run
SETUP
System CMOS checksum bad - Default
configuration used
226
table: List of POST Errors
Message
Contents
Check the [Parallel ATA] settings on the "8.2.2 Main Menu"
( pg.194) of the BIOS Setup Utility. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
Remove objects, if any, that are pressing against any keys on the
keyboard. Check to see whether the keyboard is connected
properly. If the message still appears even though the server has
been restarted, replace the keyboard. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".
Remove objects, if any, that are pressing against any keys on the
keyboard. Check to see whether the keyboard is connected
properly. If the message still appears, replace the keyboard. If
the message still appears after keyboard replacement, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
Turn the server off and check that the memory modules are
installed properly. If the message appears after the server is
turned on, check the system event log and replace the memory
modules. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of "Start Guide".
The CPU is abnormal. Check that the correct CPUs are installed.
If the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of "Start
Guide".
The memory is abnormal. Refer to the system event log and
replace the abnormal DIMM. If the message still appears, the
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
"7.3 Installing Memory Modules" (pg.166)
The memory is abnormal. Check to see that the jumper pin
settings or BIOS Setup Utility settings are correct. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
→"Chapter 8 Hardware Configuration/Utilities" ( pg.189)
The battery is abnormal. Contact an office listed in the "Contact
Information" of "Start Guide".
Correct the current settings with the BIOS Setup Utility or
restore the settings at the time of purchase. If the message still
appears, the baseboard must be replaced. Contact an office listed
in the "Contact Information" of "Start Guide".