7.2.11 Upgrading configuration from up to four to up to
eight 2.5-inch HDDs/SSDs
Upgrade and Repair Unit
(URU)
Tools: tool-less
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.

7.2.11.1 Preliminary steps

"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page 122
I
The HDD/SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all HDD/SSD modules are
uniquely identified so that you can reinsert them into their original
bays.

7.2.11.2 Installing the second HDD backplane

Ê Install the second HDD backplane as described in section
2.5-inch HDD backplane (A3C40157828)" on page
Ê If applicable, install a dual-channel RAID controller as described in section
"Installing an expansion card" on page
Ê Disconnect the SAS cable connected to the HDD backplane
(A3C40157852) from the system board connector "MLC SATA1-4" or from
the RAID controller connector "MLC1".
RX1330 M1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives