Upgrading Configuration From Up To Four To Up To Eight 2.5-Inch Hdds/Ssds; Preliminary Steps; Installing The Second Hdd Backplane - Fujitsu PRIMERGY RX2530 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2530 M1:
Table of Contents

Advertisement

7.2.11 Upgrading configuration from up to four to up to
eight 2.5-inch HDDs/SSDs
Upgrade and Repair Unit
(URU)
Tools: tool-less
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.

7.2.11.1 Preliminary steps

"Shutting down the server" on page 48
Ê
"Disconnecting the server from the mains" on page 49
Ê
"Getting access to the component" on page 49
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page 126
I
The HDD/SSD modules need not to be removed completely. But if
you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them into
their original bays.

7.2.11.2 Installing the second HDD backplane

Ê Install the second HDD backplane as described in section
2.5-inch HDD backplane (A3C40157828)" on page
Ê If applicable, install a dual-channel RAID controller as described in section
"Installing an expansion card" on page
Ê Disconnect the SAS cable connected to the HDD backplane
(A3C40157852) from the system board connector "MLC SATA1-4" or from
the RAID controller connector "MLC1".
RX2530 M1
Upgrade and Maintenance Manual
Hard disk drives / solid state drives
Hardware: 10 minutes
135.
190.
"Right side 4 x
143

Advertisement

Table of Contents
loading

This manual is also suitable for:

Primergy rx2530 m2

Table of Contents