B. Clearance to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.6).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
1 IN. MINIMUM
(25 mm)
17-5/16 IN.
(440 mm)
37-1/16 IN.
(941 mm)
27-1/16 IN.
(687 mm)
Note: The ION-V7 is the only ION appliance that can be vented with a 45 degree elbow directly off the back
positioned horizontally. See Section 4.F.
Figure 3.6 Appliance Locations
12
12 IN.
(305 mm)
Refer to Sections 10.D and 10.E for
mantel and wall projection information.
50-13/16 IN.
(1291 mm)
Heatilator • ION-V7, ION-S7, ION-H7 Installation Manual • 2276-980 Rev. E • 5/15
WARNING! Risk of Fire! Maintain specified air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with fireplace or chimney.
• Failure to maintain airspace may cause overheating and
a fire.
See Figure 3.6, 3.7, 3.8, 3.9, and 3.11 for framing
dimension requirements and required clearances.
ZERO CLEARANCE
12 IN.
ION-V7
(305 mm)
ION-S7
ION-H7
ZERO CLEARANCE
15-3/8 IN.
(391 mm)
1 IN. MINIMUM
(25 mm)
34-5/16 IN.
(872 mm)
41 IN.
(1041 mm)
20-1/8 IN.
(511 mm)