B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.5).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
G
1/2 IN.
A
D
H
CNXT4236 Series
CNXT4842 Series
Figure 3.5 Appliance Locations
12
A
B
C
TOP VENT
ONE 90º ELBOW
REAR VENT,
HORIZONTAL TERMINATION
TWO ELBOWS
B
D
A
B
in.
51
42
mm
1295
1067
in.
55-7/8
49
mm
1419
1245
Heatilator • CNXT4236IFT, CNXT4842IFT Installation Manual • 2515-980 Rev. R • 1/23
NOTICE: Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
B
ALCOVE
E
INSTALLATION
Refer to Section 10.B for mantel and wall
projection information.
Consider the mantel or cabinet system to be
installed and comply with the necessary
requirements for elevated hearth. Refer to
instructions included with cabinet system.
REAR VENT
NO ELBOWS
B
C
D
72
56-5/8
See Section 10.B.
Mantel Projections
1829
1438
79
61-1/2
See Section 10.B.
Mantel Projections
2007
1562
REAR VENT
ONE ELBOW
B
F
D
E
F
22
559
22
559
D
G
H
17-3/4
8
451
203
19-3/4
10
502
254