Alarm displays
There are three types of alarm displays:
Alarm
Where
level
1
Middle display panel
2
Lower information area
3
Lower information area
Level 1 alarms
The main alarm page is triggered by only a few parameters. This alarm page has the
highest priority and will always be displayed in the foreground.
6.6.7.6
Any alarm can be cancelled manually but if the error is not sporadic and remains
active, the alarm re-appears on the display.
Priority
Alarm
Channel
1
Water
MS4 tmot
Temp.
2
Oil Press
MS4 B
oillamp
Version: 16.12.2014
Text
Lights
ALARM
4 flashing lights
ALARM/WARN
Continuous lights
ALARM/WARN
Continuous lights
Conditions
Description
>110°C (230 °F)
Can be cancelled,
more than 2 sec.
re-trigger after 2
seconds
Bit is active
This alarm is
displayed at least
1 sec. (by means
of calculated
channel "Alarm Oil
Press Display")
Electrical System
6.6.7.5
Alarm
with
highest
priority:
the two upper LEDs of the
display are flashing.
911 GT3 Cup (991)
MY 2015
279