Odometer (6.6.5.4)
To reset the Odometer press and hold the Mark button for more than 1.5 seconds.
Label
Resolution
Total
0.1
Distance
Trip
0.001
Distance
Middle panel
Water display (6.6.5.5)
Label
PI Toolbox
Resolution
channel
Water
MS4 pwat
0.05
Press
Water
MS4 tmot
1
Temp
Water
SW09
1
Level
Water Level
Button
Fuel tank display (6.6.5.6)
Label
PI Toolbox
Resolution
channel
Fuel
Fuel Level
0.1
Level
Bargraph
Fuel Level
1
Fuel
MS4 pfuel
0.05
Press

Version: 16.12.2014

Unit
Scale
Description
km
0 - 999999.9
Cumulative channel
(0-621371 mi)
km
0 - 9999.999
Trip resets
(0-6213.71
mi)
Unit
Scale
bar
12.75 (185
psi)
Deg C
-40 to 215 (-
40 to 419 °F)
Digital
0 - 1
Unit
Scale
Liter
0 - 110.0 (0 –
29 gal)
bar
12.75 (185
psi)
6.6.5.4
Description
Value of 1
6.6.5.5
indicates
"level sensor
is immersed".
Description
Calibrated
sensor, so
min and max
could change.
Non-linear
display
6.6.5.6
911 GT3 Cup (991)