(4)
Disconnect 7 connectors.
(5)
Remove 1 screw and 1 ground wire.
Note:
Make sure that the position is correct when
inserting the connector.
(6)
Remove 8 screws, release 1 locking support,
and take off the switching regulator board.
e-STUDIO182/212/242
OUTLINE OF THE MACHINE
Connector
Green/Yellow
Black
White
White Gray
Black Brown
Locking support
© 2009 TOSHIBA TEC CORPORATION All rights reserved
2 - 26
Connector
Fig. 2-33
Fig. 2-34
Switching regulator board