Critical Error Log Messages
Automatic Server
Recovery Reset Limit
Reached
Battery Failing
Caution:
Temperature
Exceeded
Diagnostic Error
Error Detected On
Boot Up
Processor Prefailure
NMI - PCI Bus Parity
Error
NMI - Expansion
Board Error
NMI - Expansion Bus
Master Time-Out
NMI - Expansion Bus
Slave Time-Out
NMI - Fail-Safe Timer
Expiration
Processor Exception
NMI - Processor
Parity Error
Server Manager
Failure
NMI - Software
Generated Interrupt
Detected Error
Caution:
Temperature
Exceeded
Abnormal Program
Termination
ASR-2 Test Event
Message
The maximum number of system resets due to ASR-2 timer
expiration has been reached, resulting in the loading of Compaq
Utilities.
Low system battery warning. Replace battery within 7 days to
prevent loss of nonvolatile configuration memory. Failure of the
battery supporting the system's nonvolatile RAM is imminent.
The operating system has detected that the temperature of the
system has exceeded the caution level. Accompanying data in the
log notes if an auto-shutdown sequence has been invoked by the
operating system.
An error was detected by the Diagnostics Utility. See the specific
error code in this chapter for a detailed explanation.
The server detected an error during the Power-On Self-Test
(POST).
A CPU has passed an internal corrected error threshold; excessive
internal ECC cache errors .
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error condition,
resulting in a server failure.
A bus master expansion board in the indicated slot did not release
the bus after its maximum time, resulting in a server failure.
A board on the expansion bus delayed a bus cycle beyond the
maximum time, resulting in a server failure.
Software was unable to reset the system fail-safe timer, resulting in
a server failure.
The indicated processor exception occurred.
The processor detected a data error, resulting in a server failure.
An error occurred with the Server Manager/R.
Software indicated a system error, resulting in a server failure.
The operating system has detected that the temperature of the
system has exceeded the caution level. Accompanying data in the
log notes if an auto-shutdown sequence has been invoked by the
operating system.
The operating system has encountered an abnormal situation that
has caused a system failure.
The System Configuration Utility generated a test alert.
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
3-79