Compaq ProLiant 6000 Maintenance And Service Manual page 70

Hide thumbs Also See for ProLiant 6000:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . .
DAAD Diagnostic Messages
Configuration
signature mismatch
Controller
communication
failure occurred
Controller detected.
NVRAM
configuration not
present
Controller firmware
needs upgrading
Controller firmware
needs upgrading
(DAAD Error 102)
Controller is located
in special "video"
slot
Controller is not
configured
Controller needs
replacing (DAAD
Error 102)
Controller needs
replacing (DAAD
Error 104)
Message
Array accelerator board
configured for a different array
controller board. Configuration
signature on array accelerator
board does not match the one
stored on the array controller
board.
Controller communication failure
occurred.
EISA nonvolatile RAM does not
contain a configuration for this
controller.
Controller firmware is below the
latest recommended version.
Controller is correct, however,
IDA firmware version should be
greater than 1.26.
Controller is installed in slot for
special video control signals. If
controller is used in this slot, LED
indicators on front panel may not
function properly.
Controller is not configured. If
controller was previously
configured and you change drive
locations, there may be a
problem with placement of the
drives. DAAD examines each
physical drive and looks for
drives that have been moved to a
different drive bay.
IDA firmware is less than version
0.96.
The Intelligent Array Expansion
System firmware is less than
version 1.14.
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Recommended Action
To recognize the array
accelerator board, run the
System Configuration Utility.
DAAD was unable to
successfully issue commands
to the controller in this slot.
Run the System Configuration
Utility to configure the
nonvolatile RAM.
Run Options ROMPaq to
upgrade the controller to the
latest firmware revision.
Obtain the latest firmware.
Install the controller in a
different slot and run the
System Configuration Utility
to configure the controller and
nonvolatile RAM.
Look for messages indicating
which drives have been
moved. If none appear and
drive swapping did not occur,
run the System Configuration
Utility to configure the
controller and nonvolatile
RAM. Do not run the System
Configuration Utility if you
believe drive swapping has
occurred.
Replace the controller as
soon as possible.
Replace the controller as
soon as possible.
3-53

Advertisement

Table of Contents
loading

Table of Contents