DAAD Diagnostic Messages
Controller restarted
with a signature of
zero
DAAD recorded
errors attempting to
access: X
Disable command
issued
Drive (bay) X needs
replacing (DAAD
Error 102)
Drive Monitoring
features are
unobtainable
Drive Monitoring is
NOT enabled for
drive bay X
Drive time-out
occurred on physical
drive bay X
Drive (bay) X
firmware needs
upgrading
Drive (bay) X has
invalid M&P stamp
Message
DAAD did not find a valid
configuration signature to use to
get the data. Nonvolatile RAM
may not be present
(unconfigured) or the signature
present in nonvolatile RAM may
not match the signature on the
controller.
DAAD found errors while
attempting to access physical
drive X, believed to be
operational. Message followed
by specific information about the
error.
Posted writes have been
disabled by the issuing of the
Accelerator Disable command.
This occurred because of an
operating system device driver.
The 210-megabyte hard drive
has firmware version 2.30 or
2.31.
DAAD unable to get monitor and
performance data due to fatal
command problem such as drive
time-out, or unable to get data
due to these features not
supported on the controller.
The monitor and performance
features have not been enabled.
DAAD issued a command to a
physical drive and the command
was never acknowledged.
Firmware on this physical drive
is below the latest
recommended version.
Physical drive has invalid
monitor and performance data.
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Recommended Action
Run the System Configuration
Utility to configure the
controller and nonvolatile
RAM.
Replace the drive, or correct
the condition that caused the
error.
Restart the system. Run the
System Configuration Utility to
reinitialize the array
accelerator board.
Replace the drive.
Check for other errors (time-
outs, etc.). If no other errors
occur, upgrade the firmware to
a version that supports
monitor and performance, if
desired.
Run the System Configuration
Utility to initialize the monitor
and performance features.
The drive or cable may be
bad. Check the other error
messages on the Diagnostics
screen to determine
resolution.
Run the Options ROMPaq
Utility to upgrade the drive
firmware to the latest revision.
Run the System Configuration
Utility to properly initialize this
drive.
3-55