3-20 Diagnostic Tools
POST Error Messages
*1788-Incorrect
Drive Replaced:
Drive X Drive(s)
were incorrectly
replaced: Drive
Y
Select "F1" to
continue - drive
array will remain
disabled.
Select "F2" to
reset
configuration -
all data will be
lost.
*NOTE: The 1788 error message might also be displayed inadvertently due to a bad
power cable connection to the drive or by noise on the data cable. If this message was
due to a bad power cable connection, but not because an incorrect drive replacement,
repair the connection and press F2.
-Or-
If this message was not due to a bad power cable connection, and no drive replacement
took place, this could indicate noise on the data cable. Check cable for proper routing.
Continued
Audible
Error Code
Beeps
L=Long
S=Short
None
Probable Source of
Problem
Drives are not installed
in their original
positions, so the drives
have been disabled.
See note below.
Action
Reinstall the drives
correctly as indicated.
Press F1 to restart the
computer with the drive
array disabled.
-Or-
Press F2 to use the drives
as configured and lose all
the data on them.