Compaq ProLiant 6000 Maintenance And Service Manual page 28

Hide thumbs Also See for ProLiant 6000:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . .
POST Error Messages
1600-Server
Manager/R
Failure
1610-
Temperature
violation
detected.
Waiting for
system
to cool
1611-Fan failure
detected
1612-Primary
power supply
failure
1613-Low
System Battery
1701-SCSI
Controller failure
1702-SCSI
cable error
detected.
System halted.
Continued
Audible
Error Code
Beeps
L=Long
S=Short
None
2S
2S
2S
None
None
None
Probable Source of
Problem
Server Manager/R
board failure. Error
code displays after
error message.
Ambient system
temperature too hot.
Required fan not
installed or spinning.
Primary power supply
has failed.
Real time clock system
battery is running low
on power.
A test on the Fast
SCSI-2 Controller failed
Incorrect cabling.
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Action
Run Diagnostics.
Replace failed assembly
as indicated.
Check fan in system
environment.
Check fans.
Replace power supply as
soon as possible.
Run Diagnostics. Replace
failed assembly as
indicated.
Run Diagnostics. Replace
failed assembly as
indicated.
1. For Intergrated SCSI
Controllers, ensure
that the internal
connector has SCSI
termination attached.
2. For option card SCSI
controllers, ensure that
only one of the two
internal connectors
has termination
attached.
3-11

Advertisement

Table of Contents
loading

Table of Contents