DAAD Diagnostic Messages
Drive (bay) X RIS
copy mismatch
Drive (bay) X upload
code not readable
Duplicate write
memory error
Error occurred
reading RIS copy
from drive (bay) X
FYI: Drive (bay) X is
non-Compaq
supplied
Identify controller
data did not match
with NVRAM
Identify logical drive
data did not match
with NVRAM
Insufficient adapter
resources
Message
The copies of the RIS on this
drive do not match.
An error occurred while DAAD
was trying to read the upload
code information from this drive.
Data could not be written to the
array accelerator board in
duplicate due to the detection of
parity errors. This is not a data
loss situation.
An error occurred while DAAD
was trying to read the RIS from
this drive.
The installed drive was not
supplied by Compaq.
The identify controller data from
the array controller did not
match with the information
stored in nonvolatile RAM. This
could occur if new, previously
configured drives have been
placed in a system that has also
been previously configured. It
could also occur if the firmware
on the controller has been
upgraded and the System
Configuration Utility was not run.
The identify unit data from the
array controller did not match
with the information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has also
been previously configured.
The adapter does not have
sufficient resources to perform
operations to the array
accelerator board. Drive rebuild
may be occurring.
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Recommended Action
This drive may need to be
replaced. Check for other
errors.
If there were multiple errors,
this drive may need to be
replaced.
Replace the array accelerator
board.
If there were multiple errors,
this drive may need to be
replaced.
If problems exist with this
drive, replace it with a
Compaq drive.
Check the identify controller
data under the Inspect Utility.
If the firmware version field is
the only thing different
between the controller and
nonvolatile RAM data, this is
not a problem. Otherwise run
the System Configuration
Utility.
Run the System Configuration
Utility to configure the
controller and nonvolatile
RAM.
Operate the system without
the array accelerator board
until the drive rebuild
completes.
3-57