Compaq ProLiant 6000 Maintenance And Service Manual page 41

Hide thumbs Also See for ProLiant 6000:
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . .
3-24 Diagnostic Tools
POST Error Messages
1795-Drive
Array - Array
Accelerator
Configuration
Error.
Data does not
correspond to
this drive array.
Array
Accelerator is
temporarily
disabled.
1796-Drive
Array - Array
Accelerator Not
Responding.
Array
Accelerator is
temporarily
disabled.
1797-Drive
Array - Array
Accelerator
Read Error
Occurred.
Data in Array
Accelerator has
been lost.
Array
Accelerator is
disabled.
Continued
Audible
Error Code
Beeps
L=Long
S=Short
None
None
None
Probable Source of
Problem
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory.
The data stored in the
Array Accelerator does
not correspond to this
drive array.
Array Accelerator is
defective or has been
removed.
Hard parity error while
reading data from
posted writes memory.
Action
Match the Array
Accelerator to the correct
drive array, or run the
System Configuration
Utility to clear the data in
the Array Accelerator.
1. Check that the Array
Accelerator is properly
seated.
2. Run the System
Configuration Utility to
reconfigure the
Compaq IDA-2 without
the Array Accelerator.
Enable Array Accelerator.
Continued

Advertisement

Table of Contents
loading

Table of Contents