DAAD Diagnostic Messages
Drive (bay) X is a
replacement drive
marked OK
Drive (bay) X is
failed
Drive (bay) X has
insufficient capacity
for its configuration
Drive (bay) X is
undergoing drive
recovery
Drive (bay) X was
inadvertently
replaced
SCSI port X, drive
ID Y firmware needs
upgrading
Set configuration
command issued
Soft Firmware
Upgrade required
Threshold for drive
(bay) X violated
Threshold violations
Message
This drive has been replaced
and marked OK by the firmware.
This may occur if a drive has an
intermittent failure (for example,
if a drive has previously failed,
then when DAAD is run, the
drive starts working again).
The indicated physical drive has
failed.
Drive has insufficient capacity to
be used in this logical drive
configuration.
This drive is being rebuilt from
the corresponding mirror or
parity data.
The physical drive was
incorrectly replaced after
another drive failed.
Drive's firmware may cause
problems and should be
upgraded.
The configuration of the array
controller has been updated.
The array accelerator board may
remain disabled until it is
reinitialized.
DAAD has determined that your
controller is running firmware
that has been soft upgraded by
the Compaq Upgrade Utility.
However, the firmware running
is not present on all drives. This
could be caused by the addition
of new drives in the system.
This message indicates that a
monitor and performance
threshold for this drive has been
violated.
This is a list of the individual
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Recommended Action
Replace the drive.
Replace this drive.
Replace this drive with a
larger capacity drive.
Normal operations should
occur.
Replace the drive that was
incorrectly replaced and
replace the original drive that
failed. Do not run the System
Configuration Utility and try to
reconfigure; data will be lost.
Run Options ROMPaq to
upgrade the drive's firmware
to a later revision.
Run the System Configuration
Utility to reinitialize the array
accelerator board.
Run the Compaq Upgrade
Utility to place the latest
firmware on all drives.
Check for the particular
threshold that has been
violated.
The drive may need to be
3-63