DAAD Diagnostic Messages
Accelerator
status: Valid data
found at reset
Accelerator
status: Warranty
alert
Adapter/NVRAM
ID mismatch
Battery pack X
below reference
voltage
Battery X not fully
charged
Board not
attached
NVRAM
configuration
present, controller
not detected
Compatibility port
problem detected
Configuration
signature is zero
Message
Valid data was found in posted
write memory at reinitialization.
Data will be flushed to disk.
Catastrophic problem with array
accelerator board. Refer to other
messages on Diagnostics screen
for exact meaning of this
message.
EISA nonvolatile RAM has an ID
for a different controller from the
one physically present in the slot.
Battery pack on the array
accelerator is below the required
voltage levels.
Battery is not fully charged.
Array controller configured for use
with array accelerator board, but
one is not attached.
EISA nonvolatile RAM has a
configuration for an array
controller but there is no board in
this slot. Either a board has been
removed from the system or a
board has been placed in the
wrong slot.
Compatibility port configured for
this IDA controller. When DAAD
was verifying this interface, a
serious problem was detected.
DAAD detected that nonvolatile
RAM contains a configuration
signature that is zero. Old
versions of the System
Configuration Utility could cause
Continued
Description
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Recommended Action
Not an error or data loss
condition. No action needs to
be taken.
Replace the array accelerator
board.
Run the System Configuration
Utility.
Allow enough time for batteries
to recharge (36 hours). If
batteries have not recharged
after 36 hours, replace the
array accelerator board.
If 75% of the batteries present
are fully charged, the array
accelerator is fully operational.
If more than 75% of the
batteries are not fully charged,
allow 36 hours to recharge
them.
Attach array accelerator board
to array controller.
Place the array controller in the
proper slot or run the System
Configuration Utility to
reconfigure nonvolatile RAM to
reflect the removal or new
position.
A hardware problem has
occurred; replace the IDA
controller.
Run the latest version of
System Configuration Utility to
configure the controller and
nonvolatile RAM.
3-51