POST Error Messages
1772-Secondary
Disk Port
Address
Assignment
Conflict
1773-Primary
Fixed Disk Port
Assignment
Conflict
1774-Slot x
Drive Array -
Obsolete data
found in Array
Accelerator.
Select F1 to
discard contents
of Array
Accelerator.
Select F2 to
write contents of
Array
Accelerator to
drives.
1776-Drive
Array - SCSI
Port
Termination
Error
1777-Drive
Array External
Drive
Subsystem
Error
Continued
Audible
Error Code
Beeps
L=Long
S=Short
None
None
None
None
None
Probable Source of
Problem
Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Fixed disk drive error.
SMART-2 Controller
error
External and internal
SCSI drives are both
configured to Port 1.
Cooling fan failure,
internal temperature
alert or open side
panel.
Compaq ProLiant 6000 Servers Maintenance and Service Guide
Action
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Data found in Array
Accelerator is older than
data found on drives.
Press F1 to discard the
older data in the Array
Accelerator and retain the
newer data on the drives.
Reconfigure drives.
Inspect for cooling fan
failure or open side panel.