Access Panel; Optical Drive - HP ProLiant DL385 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G7:
Table of Contents

Advertisement

Remove the three T-10 Torx screws, and then detach the front bezel.
2.
To replace the component, reverse the removal procedure.

Access panel

WARNING:
internal system components to cool before touching them.
CAUTION:
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
To remove the component:
Power down the server if performing a non-hot-plug installation or maintenance procedure
1.
down the
Extend the server from the rack (on page 27).
2.
Use the T-15 Torx screwdriver attached to the rear of the server to loosen the security screw on the hood
3.
latch.
Lift up on the hood latch handle, and then remove the access panel.
4.
To replace the component, reverse the removal procedure.

Optical drive

To remove the component:
CAUTION:
all bays are populated with either a component or a blank.
Power down the server (on page 26).
1.
To reduce the risk of personal injury from hot surfaces, allow the drives and the
For proper cooling do not operate the server without the access panel, baffles,
server" on page 26).
To prevent improper cooling and thermal damage, do not operate the server unless
Removal and replacement procedures 33
("Power

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents