Fan Cage - HP ProLiant DL385 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G7:
Table of Contents

Advertisement

CAUTION:
expansion slot covers, or blanks installed. If the server supports hot-plug components, minimize
the amount of time the access panel is open.
Power down the server (on page 26).
1.
Extend or remove the server from the rack
2.
server from the
Remove the access panel
3.
CAUTION:
Detaching the cable causes any unsaved data in the cache module to be lost.
Remove the battery pack from the air baffle
4.
Remove the air baffle.
5.
To replace the component, reverse the removal procedure.

Fan cage

To remove the component:
Power down the server (on page 26).
1.
Extend or remove the server from the rack
2.
server from the
Remove the access panel
3.
Remove the PCI riser cage
4.
Remove the air baffle
5.
Remove the fan blanks.
6.
Remove the fans
7.
For proper cooling do not operate the server without the access panel, baffles,
rack" on page 27).
("Access
panel" on page 33).
Do not detach the cable that connects the battery pack to the cache module.
rack" on page 27).
("Access
panel" on page 33).
("PCI riser
cage" on page 43).
("Air
baffle" on page 53).
("Hot-plug
fan" on page 35).
("Remove the server from the
("Removing the battery
("Remove the server from the
Removal and replacement procedures 54
rack" on page 27,
"Extend the
pack" on page 49).
rack" on page 27,