Battery Replacement - HP ProLiant DL385 G7 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL385 G7:
Table of Contents

Advertisement

Remove the DIMM.
6.
To replace the component, reverse the removal procedure.

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery
that provides power to the real-time clock.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 60°C (140°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
To remove the component:
Power down the server (on page 26).
1.
Extend or remove the server from the rack
2.
server from the
Remove the access panel
3.
If any full-length expansion boards are installed, remove the full-length expansion board shipping
4.
bracket.
Remove the PCI riser cage
5.
Remove the air baffle
6.
The computer contains an internal lithium manganese dioxide, a vanadium
rack" on page 27).
("Access
panel" on page 33).
("PCI riser
cage" on page 43).
("Air
baffle" on page 53).
("Remove the server from the
Removal and replacement procedures 66
rack" on page 27,
"Extend the