Copy Of Safety Label - Regency Contura RC500EX Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

safety decal
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove. We
have printed a copy of the contents here for
your review.

Copy of Safety Label

Listed/Nom: VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certified to / Certifi : é CSA/ANSI Z21.88:19 • CSA-2.33:19
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Refer to Intertek's Directory of Building Products for detailed information.
C # 4001172
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
FACTORY EQUIPPED FOR NATURAL GAS
Model:RC500EX-NG
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
FACTORY EQUIPPED FOR PROPANE GAS
Model:RC500EX-LP
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Maximum Input
Minimum Input
Orifice size
Altitude
Minimum Clearances to Combustibles/Dégagements minimaux aux matériaux combustibles
Minimum ceiling height from top of unit:15"/381mm
Hauteur du plafond min. depuis le dessus de
l'appareil : 15"/381mm
A* 9"/229mm
B 2"/50mm
E 4"/102mm
C 2" / 50mm
F 50"/1270mm
* See unit manual for Alcove Clearances
Minimum clearance of Vent Terminal
to Outside Corner & Inside Corner:
with AstroCap 6"/150mm
with Dura-Vent Cap 12"/300mm
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with
the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such a
standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2
ou NFPA 501C Standard for Recreational Vehicles.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. See owner's
manual for details. This appliance is supplied with a conversion kit.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation
ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de
camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. En l'absence de telles
normes, suivre la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2
ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le(s) type(s) de gaz indiqué(s) sur la plaque signalétique. Cet appareil peut être
installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le
permettent. Voir le manuel d'utilisation pour plus de détails. Cet appareil est livré avec une trousse de conversion. Système
de ventilation (Part # 910-215/P)
For Use Only with Barrier (Part # 366-929/366-949) or (Part # 366-060/366-063). Follow installation instructions.
Utiliser uniquement avec l'écran (Pièce n° 366-929/366-949) ou (Pièce n° 366-060/366-063). Suivre les instructions d'installation.
ELECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE :115V_60HZ less than/moins de 2 AMP. CATEGORY I/CATÉGORIE I.
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
FOYER AU GAZ À ÉVACUATION -
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY.
À UTILISER UNIQUEMENT AVEC LES PORTES VITRÉES CERTIFIÉES
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada/Fabriqué au Canada
CANADIAN ENERGY
CSA P.4.1 Fireplace Efficiency (FE) / Efficacité énergétique des foyers (EEF) CSA P.4.1
PERFORMANCE
VERIFIED
Natural Gas / Gaz naturel 60.38%
RENDEMENT
Propane Gas / Gaz propane 61.42%
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Part #: 920-515
For the State of Massachusetts, installation and repair must be done by a plumber or gas fitter licensed in the
Commonwealth of Massachusetts.
Colour:
Everything black on grey except for items indicated as being printed in red.
Size:
Printed at 100% 5.996''W x 9.282''H
For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.
May 03/22: Created decal
Material: Printable white polyester 7mm
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
*Printer: Start serial sequence @ 000001
NOTE: This is a double sided decal
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720
and a CO alarm with battery back up in the same room where the gas appliance is installed.
4
| RC500EX
NOTE: Regency
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
DUPLICATE SERIAL NO.
CSA 2.17-2017
APPAREIL FONCTIONNANT AU GAZ NATUREL
Modèle :RC500EX-NG
5"
WC/C.E. (1.25 kPa)
Pression d'alimentation minimale
3.5" WC/C.E. (0.87 kPa)
Pression manifold lev e
1.6" WC/C.E. (0.40 kPa)
Pression manifold basse
23,000 Btu/h (6.74 Kw/h)
D bit calorifique maximal
é
D bit calorifique minimal
é
16,000 Btu/h (4.69 Kw/h)
#43 DMS
(2.37mm)
Taille de l'orifice
0-4500 ft/pi (0-1372m)
Altitude
APPAREIL FONCTIONNANT AU GAZ PROPANE
Modèle :RC500EX-LP
11" WC/C.E.
(2.74 kPa)
Pression d'alimentation minimale
Pression
10" WC/C.E.
(2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
Pression manifold basse
D bit calorifique maximal
é
22,000 Btu/h (6.45 Kw/h)
D bit calorifique minimal
é
18,000 Btu/h (5.28 Kw/h)
Taille de l'orifice
#54 DMS
(1.4mm)
Altitude
0-4500 ft/pi (0-1372m)
Left Side Wall
F
Horizontal
Pipe
F
Right Side Wall
Fan Kit (Part # 910-215/P)
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
.
units are constantly being
®
573
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
573
Serial No./ No de série
é
é
manifold é
lev e
é
Left Side Wall
Vertical
Pipe
Right Side Wall
920-515
Label Location
Open up the lower front door to locate the label
which will be sitting on the base with black chain
affixed to it. See below.
Open d
Remov
Contro
pairing

Advertisement

Table of Contents
loading

This manual is also suitable for:

Contura rc500ex-ngContura rc500ex-lp

Table of Contents