Vertical Termination With Co-Linear Flex System Into A Masonry Chimney - Regency P36D-LP10 Owners & Installation Manual

P36d zero clearance direct vent gas fireplace
Hide thumbs Also See for P36D-LP10:
Table of Contents

Advertisement

installation
|
30
VERTICAL TERMINATION
WITH CO-LINEAR FLEX SYSTEM INTO A MASONRY CHIMNEY
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. See the Venting
Arrangements on next page for minimum and
maximum heights.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
510-994
Rigid Pipe Adaptor
FPI Cabinet and/or Flat Wall Mantles may
be used in these applications ensuring
that clearances to combustibles are
maintained.
30 |
®
Regency
P36D-10 Zero Clearance Direct Vent Gas Fireplace
Masonry chimneys may take various contours which the flexible liner will accommodate. However,
keep the flexible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
of two certified
may be used
#948-305 (35 ft)
Outer
Pipe
with Kit#
946-563
Pipe Length
Rigid Pipe Adapter
# 510-994
Co-linear DV
Vertical Termination
Cap # 946-529
A maximum
joiner kits
per length.
Exhaust
Flue
90 Degree
Elbow
Inner Pipe
Adapter
with Kit#
946-563
Flex Liner
Air Intake
Co-Linear
Flex
Adapter
with Kit#
946-563

Hide quick links: