Toggling The Center Mode And Fixed Mode - Kenwood TS-990S Instruction Manual

Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

7 BANDSCOPE
CONFIGURING THE WATERFALL DISPLAY FALL
SPEED
The fall speed of the waterfall display can be configured.
1 Press [SPEED] (F4) to select the waterfall speed.
• Each time you press [SPEED] (F4), the fall speed cycles
through "Speed 1" (60 seconds) > "Speed 2" (20 seconds)
> "Speed 3" (8 seconds) > "Speed 1". The default is
"Speed 3".
• If [SPEED] (F4) is unavailable in the key guide, press
[MORE] (F1).
• Each long press of [SPEED] (F4) cycles the fall speed in
the reversed sequence.
CHANGING THE DISPLAY OF THE BANDSCOPE (MAIN
BAND AND SUB BAND)
The signal to be displayed in the bandscope can be
selected from the main band signal or sub band signal.
Follow the procedure below while the bandscope appears.
1 Press [M/S] (F2) to toggle the selected band between
the main band and the sub band.
• Each time you press [M/S] (F2), the selection toggles
between [MAIN] and [SUB]. Each time the selection is
toggled, the markers for the lower limit frequency displayed
on the upper left side of the grid, and the upper limit
frequency displayed on the upper right side of the grid will
change.
• If [M/S] (F2) is unavailable in the key guide, press [MORE]
(F1).
7-2
DISPLAYING THE BANDSCOPE AND ANOTHER
SCREEN
You can display the bandscope while the RTTY Encode/
Decode or PSK Encode/Decode screen appears,
provided that the transceiver is in FSK or PSK mode or the
configuration screen is displayed.
Press [SCP] to display the Bandscope screen with
the scale in the vertical direction compressed to 1/3.
The [RF/AF] (F2), [ATT] (F5), or other function keys
for the bandscope do not appear along the bottom of
the main screen while the bandscope appears coupled
with the other screen; hence, you cannot change the
configurations for the bandscope.
[F1] [F7]
[SCP]

TOGGLING THE CENTER MODE AND FIXED MODE

There are two modes available, the Center mode which
always places the receive frequency at the center of the
bandscope, and the Fixed mode which displays fixed
lower and upper frequency limits.
Follow the procedure below while the bandscope appears.
1 Press [CRT/FIX] (F3) to change the display.
• Each time you press [MODE] (F7), the selection toggles
between "CENTER MODE" and "FIXED MODE".
• If [CTR/FIX] (F3) is unavailable in the key guide, press
[MORE] (F1).
Note:
◆ In Fixed mode, with the observation of the target signal (vertical
trace) displayed on the Waterfall, shift the marker position to tune
the signal. This enables you to tune more easier than in Center
mode.
[MENU]
Index
Contents

Advertisement

Table of Contents
loading

Table of Contents