Changing The Cutoff Frequencies (Low And High Frequency) To Adjust The Passband Width Characteristics - Kenwood TS-990S Instruction Manual

Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

6 REJECTING INTERFERENCE
CHANGING THE CUTOFF FREQUENCIES (LOW
AND HIGH FREQUENCY) TO ADJUST THE
PASSBAND WIDTH CHARACTERISTICS
In the SSB, AM, or FM mode, you can modify the
passband width of the filter by changing the cutoff
frequencies (low and high frequency).
You can change the pass bandwidth so that interference will
be outside the bandwidth of the filter.
Low Cut Frequency Range
Target Signal
Interfering
Signal
0 Hz 1 KHz
[ESC]
Mode keys
1 Press one of mode keys to select LSB, USB, FM, or
AM mode.
2 Press and hold [FIL/SEL] (M) or [FIL/SEL] (S) to open
the RX Filter screen.
The selected band and the mode name while receiving
appear, and the selected RX filter (A, B, or C) is activated.
3 Rotate either HI/SHIFT or LO/WIDTH control.
• Rotating the HI/SHIFT control clockwise increases the
high cutoff frequency and rotating it counterclockwise
decreases the high cutoff frequency.
• Rotating the LO/WIDTH control clockwise increases the
low cutoff frequency and rotating it counterclockwise
decreases the high cutoff frequency.
• The changes of the shift and filter type appear on the RX
Filter screen.
6-6
High Cut Frequency Range
Interfering
Signal
5 KHz
[HI/SHIFT]
[LO/WIDTH]
[FIL/SEL] (M)
[FIL/SEL] (S)
4 Press [ESC] to exit.
Pressing [FIL/SEL] (M) or [FIL/SEL] (S) closes the RX Filter
screen.
Note:
◆ You can view the progress of adjustments while the sub-scope
appears on the sub-screen.
Cutoff frequency (low) (Hz)
Mode
Range
0, 50, 100, 200,
LSB/USB/
300, 400, 500,
FM
600, 700, 800,
900, 1000
AM
0, 100, 200, 300
Cutoff frequency (high) (Hz)
Default
Range
Default
1000, 1200, 1400,
1600, 1800, 2000,
200
2200, 2400, 2600,
2800
2800, 3000, 3400,
4000, 5000
2500, 3000, 4000,
100
5000
5000