The List Of Error Messages - Kenwood TS-990S Instruction Manual

Hide thumbs Also See for TS-990S:
Table of Contents

Advertisement

18 TROUBLESHOOTING

THE LIST OF ERROR MESSAGES

An error message appears when the transceiver detects any failure or abnormality. A problem can be cured following
the description on the error message. If reading of "Troubleshooting" is required on the error message or if you cannot
cure the problem, refer to the List of Error Messages and Troubleshooting.
ID
Configurations for the Local Clock have not been completed.
(ERR: 0017)
0017
Associated functions cannot be used until the timer
configurations have been completed.
Connection to an NTP server has failed. (ERR: 001F)
001F
Ensure that the NTP server address and the network have been
correctly configured.
0025 A file is invalid. (ERR: 0025)
An error occurred while a file was being read from a USB flash
0026
drive. (ERR: 0026)
A failure in detecting the firmware file will terminate the firmware
updating process. (ERR: 0040)
The termination of the firmware update may be caused by the
following:
• The firmware file is not stored in the specified folder.
• The USB flash drive is not in the specified format. The
0040
USB flash drive must be formatted in the USB Flash Drive
Management screen.
• The newer version firmware has already been applied to the
transceiver.
• The firmware file is not legitimate.
Restart the transceiver and then execute the firmware update
again from the beginning.
A failure in detecting the firmware file will terminate the firmware
0041
updating process. (ERR: 0041[xxx])
Refer to the list of messages in the instruction manual.
A USB flash drive cannot be detected. (ERR: 0043)
Failure to detect the USB flash drive may be caused by the
following.
• The USB flash drive is not correctly connected to a USB
0043
connector.
• The USB flash drive is not in the specified format. The
USB flash drive must be formatted in the USB Flash Drive
Management screen.
The current sourced from the USB connector exceeds the
0044
upper limit value. (ERR: 0044)
Remove the USB device and then restart the transceiver.
An error occurs while a file is being written to an internal
0045
memory area or a USB flash drive. (ERR: 0045)
PLL unlock was detected. (ERR: 0048 [xxx])
0048
Refer to the list of messages in the instruction manual.
Abnormal cooling fan behavior has been detected. Refer to
"Troubleshooting" in the instruction manual. (ERR: 0050)
0050
Transmission capability is disabled while this error message
appears on the main screen.
Very high temperature has been detected in the power supply
unit. Refer to "Troubleshooting" in the instruction manual. (ERR:
0051)
0051
The transceiver cannot transmit until the transceiver cools
down.
DO NOT turn the transceiver main power OFF, and leave the
transceiver until it cools down.
Overheating has been detected in the power supply unit. Refer
to "Troubleshooting" in the instruction manual. (ERR: 0052)
0052
The transceiver power (
seconds to prevent the transceiver from being overheated.
18-4
Message
) will soon be turned OFF in n
Outline and What to do
Appears when you attempt to activate the Program Timer without
configuring the local clock. The local clock can be configured in the CLOCK
menus 00 to 03.
Appears when the date and time data cannot be acquired from an NTP
server.
Follow the instruction given on an error message.
Appears when an error was detected from a file when the RX Equalizer, TX
Equalizer or configuration data is stored.
Appears when an error was detected from a file when the RX Equalizer, TX
Equalizer or configuration data stored in the USB flash drive is read.
Appears if any failure was detected while reading the firmware file.
Follow the instruction given on an error message.
Appears if any failure was detected while writing the firmware file.
Update the transceiver firmware again. If writing of the transceiver
repeatedly fails, note the error message number (ERR: 0040) and
the number enclosed with the angle brackets ([xxx]) and contact the
KENWOOD service center.
Appears if no USB flash drive is detected.
Follow the instruction given on an error message.
Appears when over current is detected from the USB connector. Disconnect
the unused USB devices.
The occurred error might be caused by one or more of the following causes.
• As a result of the storing of the multiple files at a time, the same name
might be given to the multiple files.
• You attempted to store files exceeding the maximum file numbers that can
be stored in the transceiver (255 files).
• Any error was detected while writing a file.
Appears when an PLL unlock was detected.
Full Reset is required. Still the PLL unlock is detected, note the error
message number (ERR: 0048), and contact the KENWOOD service center.
Appears when an error was detected from a cooling fan.
If an error message does not disappear even after the transceiver cools
down, note the error message number (ERR: 0050), and contact the
KENWOOD service center.
Appears when an error was detected from the power supply unit.
Keep activating the cooling fan without shutting down the main power (I/O).
If an error message does not disappear even after the transceiver cools
down, note the error message number (ERR: 0051), and contact the
KENWOOD service center.
Appears when an error was detected from the power supply unit. The
transceiver turns OFF.
Keep activating the cooling fan without shutting down the main power (I/O).
If this error message frequently appears, note the error message number
(ERR: 0052), and contact the KENWOOD service center.
Index