Manuals and User Guides for SMC Sierra Monitor FPC-N38. We have
2
SMC Sierra Monitor FPC-N38 manuals available for free PDF download: Startup Manual
SMC Sierra Monitor FPC-N38 Startup Manual (43 pages)
For Interfacing Riello Array Boilers: 905, To Building Automation Systems: BACnet MS/TP, BACnet/IP, Modbus TCP/IP, Metasys N2 and LonWorks
Brand:
SMC Sierra Monitor
| Category:
Server
| Size: 2 MB
Table of Contents
Table of Contents
4
1 Certification
6
BTL Mark - Bacnet Testing Laboratory
6
Lonmark Certification
6
2 Introduction
7
Protonode Gateway
7
3 Protonode Setup
8
Record Identification Data
8
Point Count Capacity and Registers Per Device
8
Figure 1: Protonode Part Numbers
8
Figure 2: Supported Point Count Capacity
8
Figure 3: Registers Per Device
8
Configuring Device Communications
9
3.3.1 Input COM Settings on All Devices Connected to the Protonode
9
3.3.2 Set Modbus RTU Node-ID for each Device Attached to the Protonode
9
Figure 4: Modbus COM Settings
9
Selecting the Desired Field Protocol and Enabling Auto-Discovery
10
3.4.1 Selecting Desired Field Protocol
10
Figure 5: S Bank DIP Switches
10
3.4.2 Enabling Auto-Discovery
11
Figure 6: S3 DIP Switch Setting for Auto Discovering Devices
11
BMS Network Settings: MAC Address, Device Instance and Baud Rate
12
3.5.1 Bacnet MS/TP (FPC-N38): Setting the MAC Address for BMS Network
12
Figure 7: MAC Address DIP Switches
12
3.5.2 Bacnet MS/TP (FPC-N38): Setting the Baud Rate for BMS Network
13
Baud Rate DIP Switch Selection
13
Figure 8: BMS Baud Rate DIP Switches
13
Figure 9: BMS Baud Rate
13
4 Interfacing Protonode to Devices
14
Protonode FPC-N38 and FPC-N39 Showing Connection Ports
14
Figure 10: Protonode FPC-N38 (Upper) and Protonode FPC-N39 (Lower)
14
Device Connections to Protonode
15
Figure 11: Power and RS-232 Connections
15
Bacnet MS/TP or Metasys N2 (FPC-N38): Wiring Field Port to RS-485 Network
16
Lonworks (FPC-N39): Wiring Lonworks Devices to the Lonworks Terminal
16
Figure 12: Connection from Protonode to RS-485 Field Network
16
Figure 13: RS-485 BMS Network EOL Switch
16
Figure 14: Lonworks Terminal
16
Power-Up Protonode
17
Figure 15: Required Current Draw for the Protonode
17
Figure 16: Power Connections
17
4.5.1 Auto-Discovery: after Completion - Turn off to Save Configuration
18
Figure 17: S3 DIP Switch Setting for Auto Discovering Devices
18
5 Bacnet/Ip or Modbus TCP/IP: Change the Protonode IP Address
19
Connect the PC to Protonode Via the Ethernet Port
19
Bacnet/Ip and Modbus TCP/IP: Setting IP Address for Field Network
20
Figure 18: Web Configurator Screen
20
Figure 19: Changing IP Address Via FS-GUI
21
6 Bacnet MS/TP and Bacnet/Ip: Setting Node_Offset to Assign Specific Device Instances
22
Figure 20: Web Configurator Screen with Active Profiles
22
7 How to Start the Installation Over: Clearing Profiles
23
8 Lonworks (FPC-N39): Commissioning Protonode on a Lonworks Network
24
Commissioning Protonode FPC-N39 on a Lonworks Network
24
8.1.1 Instructions to Download XIF File from Protonode FPC -N39 Using Browser
24
Figure 21: Lonworks Service Pin Location
24
Figure 22: Sample of Fserver.xif File Generated
25
9 Bacnet Explorer
26
Figure 23: Bacnet Explorer on a Bacnet Network
26
Appendix A. Troubleshooting
27
Appendix A.1. Lost or Incorrect IP Address
27
Figure 24: Ethernet Port Location
27
Appendix A.2. Viewing Diagnostic Information
28
Figure 25: Error Messages Screen
28
Appendix A.3. Checking Wiring and Settings
29
Appendix A.4. LED Diagnostics for Communications between Protonode and Devices
30
Figure 26: Diagnostic Leds
30
Appendix A.5. Taking Diagnostic Capture with the Fieldserver Toolbox
31
Figure 27: Ethernet Port Location
31
Appendix A.6. Updating Firmware
34
Appendix A.7. Bacnet: Setting Network_Number for more than One Protonode on Subnet
34
Figure 28: Web Configurator - Setting Network Number for Bacnet
34
Appendix A.8. Securing Protonode with Passwords
35
Appendix B. Vendor Information - Riello
36
Appendix B.1. 905 Modbus RTU Mappings to Bacnet, Metasys N2 and Lonworks
36
Appendix C. "A" Bank DIP Switch Settings
39
Appendix C.1. "A" Bank DIP Switch Settings
39
Appendix D. Reference
42
Appendix D.1. Specifications
42
Appendix D.1.1. Compliance with UL Regulations
42
Figure 29: Specifications
42
Appendix E. Limited 2 Year Warranty
43
Advertisement
SMC Sierra Monitor FPC-N38 Startup Manual (37 pages)
ProtoNode
Brand:
SMC Sierra Monitor
| Category:
Network Hardware
| Size: 2 MB
Table of Contents
Table of Contents
3
List of Figures
4
1 Introduction
5
2 Certification
6
BTL Mark - Bacnet Testing Laboratory
6
Lonmark Certification
6
3 Bacnet/Lonworks Setup through Protonode
7
Features
7
Installation Steps for the Customer
7
Record Identification Data
7
Configure the DIP Switches
8
Setting the Node/ID Device Instance (DIP Switch A0 - A7)
8
Setting the Serial Baud Rate (DIP Switch B0 - B3)
8
Figure 1: A0 - A7 DIP Switches
8
Figure 2: B0 - B3 DIP Switches
8
3.4.3 Select and Load Configuration Files
9
Figure 3: BMS Baud Rate
9
Figure 4: S0 - S3 DIP Switches
9
4 Interfacing Protonode to Host OEM Device
10
Protonode FPC-N34 and FPC-N35 Showing Connection Ports
10
Figure 5: Protonode Bacnet FPC-N34 (Upper) and Protonode FPC-N35 (Lower)
10
Device Connections to Protonode
11
Figure 6: R2 Port
11
Figure 7: Power and RS-485 Connections
11
Resistor and Power Jumper Information
12
4.3.1 Bias Resistors
12
Figure 8: Bias Resistors
12
4.3.2 Termination Resistor
13
Figure 9: Termination Resistor
13
4.3.3 Power Jumper Settings
14
Figure 10: Power Jumper Switch
14
Wiring Field Port to RS-485 BMS Network
15
Wiring Field Port to a Lonworks Network
15
Figure 11: Connection from Protonode to RS-485 Field Network
15
Figure 12: RS-485 BMS Network EOL Switch
15
Figure 13: Lonworks Terminal
15
Power-Up Protonode
16
Figure 14: Required Current Draw for the Protonode
16
Figure 15: Power Connections
16
6 Connect the Protonode's Web GUI to Setup IP Address for Ethernet Network
17
Connect the PC to Protonode Via the Ethernet Port
17
Setting IP Address for Field Network
18
Figure 18: Web Configurator Screen with Active Profiles
18
Figure 19: Changing IP Address Via Web GUI
19
5 Lonworks (FPC-N35): Commissioning Protonode on a Lonworks Network
20
Commissioning Protonode FPC-N35 on a Lonworks Network
20
6.1.1 Instructions to Download XIF File from Protonode FPC -N35 Using Browser
20
Figure 16: Lonworks Service Pin Location
20
Figure 17: Sample of Fserver.xif File Being Generated
21
Appendix A. Troubleshooting
22
Appendix A.1. Lost or Incorrect IP Address
22
Figure 20: Ethernet Port Location
22
Appendix A.2. Viewing Diagnostic Information
23
Figure 21: Error Messages Screen
23
Appendix A.3. Check Wiring and Settings
24
Appendix A.4. LED Diagnostics for Communications between Protonode and Devices
25
Figure 22: Diagnostic Leds
25
Appendix A.5. Take Diagnostic Capture with the Fieldserver Toolbox
26
Figure 23: Ethernet Port Location
26
Appendix A.6. Update Firmware
29
Appendix A.7. Bacnet: Setting Network_Number for more than One Protonode on Subnet
29
Figure 24: Web Configurator - Setting Network Number for Bacnet
29
Appendix A.8. Passwords
30
Appendix A.9. Reading Data Arrays
30
Appendix B. Vendor Information
31
Appendix B.1. Additional DIP Switch Settings
31
Figure 25: Additional DIP Switches
31
Appendix C. Reference
32
Appendix C.1. Specifications
32
Figure 26: Specifications
32
Appendix C.1.1. Compliance with UL Regulations
33
Appendix D.1. "A" Bank DIP Switch Settings
34
Appendix D. Bank DIP Switch Settings
34
Appendix E. Limited 2 Year Warranty
37
Advertisement
Related Products
SMC Sierra Monitor ProtoNode FPC-N34
SMC Sierra Monitor ProtoNode FPC-N35
SMC Sierra Monitor FPC-N36
SMC Sierra Monitor FPC-N37
SMC Sierra Monitor FPC-N39
SMC Sierra Monitor FPC-N41
SMC Sierra Monitor FPC-N40
SMC Sierra Monitor FPC-N42
SMC Sierra Monitor ProtoNode FPC-N54
SMC Sierra Monitor Pure Humidifier ProtoAir FPA-W44
SMC Sierra Monitor Categories
Gateway
Server
Network Router
Security Sensors
Network Hardware
More SMC Sierra Monitor Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL