Manuals and User Guides for Daikin SkyAir RZR48TAVJU. We have
5
Daikin SkyAir RZR48TAVJU manuals available for free PDF download: Service Manual, Installation Manual, Installation Instructions Manual
Daikin SkyAir RZR48TAVJU Service Manual (331 pages)
Cooling Only 60 Hz, Heat Pump 60 Hz
Brand:
Daikin
| Category:
Air Conditioner
| Size: 19.52 MB
Table of Contents
Table of Contents
2
Introduction
7
Safety Cautions
8
Warnings and Cautions Regarding Safety of Workers
8
Warnings and Cautions Regarding Safety of Users
10
Icons Used
13
Revision History
14
Part 1 General Information
15
Model Names and Power Supply
16
Compatibility Table
16
Cooling Only
17
Heat Pump
18
External Appearance
19
Indoor Unit
19
Outdoor Unit
20
Remote Controller
21
Specifications
22
Cooling Only
22
Heat Pump
48
Part 2 Refrigerant Circuit
74
Refrigerant Circuit (Piping Diagrams)
75
Rzr18/24Tavju, Rzq18/24Tavju
75
Refrigerant Circuit Part
75
Rzr30/36/42/48Tavju, Rzq30/36/42/48Tavju
77
Indoor Unit
79
Functional Parts Layout
80
Rzr18/24Tavju, Rzq18/24Tavju
80
Rzr18/24Tavjua, Rzq18/24Tavjua
82
Rzr30/36/42/48Tavju, Rzq30/36/42/48Tavju
84
Rzr30/36/42/48Tavjua, Rzq30/36/42/48Tavjua
86
Part 3 Remote Controller
88
Applicable Models
89
Names and Functions
90
Wired Remote Controller
90
Simplified Remote Controller
93
Wireless Remote Controller
94
Main/Sub Setting
96
Wired Remote Controller (BRC1E73)
96
When Wireless Remote Controller Is Used Together
97
Address Setting for Wireless Remote Controller
98
Centralized Control Group No. Setting
101
Brc1E73
101
Wireless Remote Controller
103
Service Settings Menu, Maintenance Menu
104
Brc1E73
104
Wireless Remote Controller
108
Part 4 Functions and Control
109
Operation Mode
110
Basic Control
111
Normal Operation
111
Compressor PI Control
112
Electronic Expansion Valve PI Control
114
Cooling Operation Fan Control
115
Special Control
116
Startup Control
116
Oil Return Control
118
Defrost Control
120
Pump down Residual Control
121
Restart Standby
122
Stop Control
122
Protection Control
123
High Pressure Protection Control
123
Low Pressure Protection Control
124
Discharge Pipe Temperature Protection Control
126
Inverter Protection Control
127
Other Control
129
Demand Operation
129
Heating Operation Prohibition
129
Outline of Control (Indoor Unit)
130
Remote Controller Thermistor
130
Thermostat Control
132
Thermostat Control with Operation Mode Set to AUTO
134
List of Swing Flap Operations
135
Hot Start Control (in Heating Operation Only)
136
Louver Control for Preventing Ceiling Dirt (FCQ Models Only)
137
Drain Pump Control
138
Freeze-Up Prevention
140
Heater Control (Except FTQ-TA Models)
142
Heater Control (FTQ-TA Models)
143
3-Step Thermostat Processing (FTQ-TA Models)
147
Fan Control (Heater Residual) (FTQ-TA Models)
148
Interlocked with External Equipment (FTQ-TA Models)
148
Part 5 Field Settings and Test Operation
150
Field Setting from Remote Controller
151
Wired Remote Controller
151
Simplified Remote Controller
153
Wireless Remote Controller
154
List of Field Settings for Indoor Unit
155
Details of Field Settings for Indoor Unit
159
Operation Control Mode
174
Field Settings from Outdoor Unit
175
Capacity Setting
175
Setting Mode and Monitor Mode
176
Setting Mode 1
177
Setting Mode 2
179
Monitor Mode
183
Setting of Low Noise Operation and Demand Operation
185
Setting of Refrigerant Recovery Mode
188
Setting of Vacuuming Mode
188
Check Operation
189
Setting of Auxiliary Heater Control
190
Setting of Heat Pump Lockout and Emergency Heat Mode
191
Test Operation
193
Check Work Prior to Turning Power Supply on
193
Turn Power on
193
Test Operation
194
Error Codes and Corresponding Measures
197
When Turning on Power First Time
199
When Turning on Power the Second Time and Subsequent
199
When an Indoor Unit or Outdoor Unit Has Been Added, or Indoor or Outdoor Unit PCB Has Been Changed
199
Part 6 Service Diagnosis
200
Servicing Items to be Confirmed
203
Troubleshooting
203
Precautions for Maintenance
203
Refrigerant Properties (R-410A)
205
Symptom-Based Troubleshooting
206
Indoor Unit Overall
206
With Optional Infrared Presence/Floor Sensor
209
Troubleshooting with Remote Controller
211
Wired Remote Controller
211
Wireless Remote Controller
212
Troubleshooting by Error Codes
214
Error Codes and Description
214
Error Codes - Sub Codes
216
Error Code Indication by Outdoor Unit PCB
218
External Protection Device Abnormality (Except FTQ-TA)
222
External Protection Device Abnormality (FTQ-TA Only)
223
Indoor Unit PCB Abnormality
224
Drain Level Control System (S1L) Abnormality
225
Indoor Fan Motor (M1F) Lock, Overload
227
Indoor Fan Motor Abnormality
229
Blower Motor Not Running
233
Indoor Fan Motor Status Abnormality
234
Low Indoor Airflow
235
Swing Flap Motor Abnormality
236
Power Supply Voltage Abnormality
238
Blower Motor Stops for Over/Under Voltage
239
Electronic Expansion Valve Coil Abnormality, Dust Clogging
240
Drain Level above Limit
242
Defective Capacity Setting
243
Transmission Abnormality (between Indoor Unit PCB and Fan PCB)
244
Blower Motor Communication Error
246
Thermistor Abnormality
247
Combination Abnormality (between Indoor Unit PCB and Fan PCB)
248
Blower Motor HP Mismatch
249
Indoor Blower Does Not Have Required Parameters to Function
250
Remote Sensor Abnormality
251
Infrared Presence/Floor Sensor Error
252
Remote Controller Thermistor Abnormality
257
Outdoor Main PCB Abnormality
258
Activation of High Pressure Switch
259
Activation of Low Pressure Sensor
261
Inverter Compressor Motor Lock
263
Outdoor Fan Motor Abnormality
265
Electronic Expansion Valve Coil Abnormality
267
Discharge Pipe Temperature Abnormality
268
Refrigerant Overcharged
269
Thermistor Abnormality
270
High Pressure Sensor Abnormality
271
Low Pressure Sensor Abnormality
272
PCB (for Inverter Compressor) Abnormality
273
Radiation Fin Temperature Rise Abnormality
274
Inverter Compressor Instantaneous Overcurrent
275
Inverter Compressor Overcurrent
276
Inverter Compressor Startup Abnormality
277
Transmission Error (between Microcomputers on the Outdoor Main PCB)
278
Inverter Circuit Capacitor High Voltage
279
Radiation Fin Thermistor Abnormality
280
Refrigerant Shortage
281
Power Supply Insufficient or Instantaneous Abnormality
283
Check Operation Not Executed
285
Transmission Error between Indoor Units and Outdoor Units
286
Transmission Error between Remote Controller and Indoor Unit
288
Transmission Error between Main and Sub Remote Controllers
289
Transmission Error between Indoor and Outdoor Units in the same System
290
Improper Combination of Indoor and Outdoor Units, Indoor Units and Remote Controller
291
Incorrect Electric Heater Capacity Setting
293
Address Duplication of Centralized Controller
294
Transmission Error between Centralized Controller and Indoor Unit
295
System Not Set
296
System Abnormality, Refrigerant System Address Undefined
297
Check
298
High Pressure Check
298
Low Pressure Check
299
Superheat Operation Check
300
Power Transistor Check
301
Refrigerant Overcharge Check
302
Refrigerant Shortage Check
303
Vacuuming and Dehydration Procedure
304
List of Inverter-Related Error Codes
305
Concept of Inverter-Related Error Codes
306
Thermistor Check
307
Pressure Sensor Check
310
Broken Wire Check of the Relay Wires
311
Fan Motor Connector Check
312
Electronic Expansion Valve Coil Check
314
Fan Motor Connector Check for FTQ-TA
317
Part 7 Appendix
321
Wiring Diagrams
322
Outdoor Unit
322
Indoor Unit
326
Advertisement
Daikin SkyAir RZR48TAVJU Service Manual (298 pages)
Cooling Only 60 Hz Heat Pump 60 Hz
Brand:
Daikin
| Category:
Air Conditioner
| Size: 18.22 MB
Table of Contents
Table of Contents
2
Introduction
7
Safety Cautions
8
Warnings and Cautions Regarding Safety of Workers
8
Warnings and Cautions Regarding Safety of Users
10
Icons Used
13
Revision History
14
Part 1 General Information
15
Model Names and Power Supply
16
Cooling Only
16
Heat Pump
17
External Appearance
18
Indoor Unit
18
Outdoor Unit
19
Remote Controller
20
Specifications
21
Cooling Only
21
Heat Pump
34
Part 2 Refrigerant Circuit
47
Refrigerant Circuit (Piping Diagrams)
48
Rzr18/24Tavju, Rzq18/24Tavju
48
Refrigerant Circuit Part
48
Rzr30/36/42/48Tavju, Rzq30/36/42/48Tavju
50
Indoor Unit
52
Functional Parts Layout
53
Rzr18/24Tavju, Rzq18/24Tavju
53
Rzr30/36/42/48Tavju, Rzq30/36/42/48Tavju
55
Part 3 Remote Controller
57
Applicable Models
58
Names and Functions
59
Wired Remote Controller
59
Simplified Remote Controller
62
Wireless Remote Controller
63
Main/Sub Setting
65
Wired Remote Controller (BRC1E73)
65
When Wireless Remote Controller Is Used Together
66
Address Setting for Wireless Remote Controller
67
Centralized Control Group No. Setting
70
Brc1E73
70
Wireless Remote Controller
72
Service Settings Menu, Maintenance Menu
73
Brc1E73
73
Wireless Remote Controller
77
Part 4 Functions and Control
78
Operation Mode
79
Basic Control
80
Normal Operation
80
Compressor PI Control
81
Electronic Expansion Valve PI Control
83
Cooling Operation Fan Control
84
Special Control
85
Startup Control
85
Oil Return Control
87
Defrost Control
89
Pump down Residual Control
90
Restart Standby
91
Stop Control
91
Protection Control
92
High Pressure Protection Control
92
Low Pressure Protection Control
93
Discharge Pipe Temperature Protection Control
95
Inverter Protection Control
96
Other Control
98
Demand Operation
98
Heating Operation Prohibition
98
Outline of Control (Indoor Unit)
99
Remote Controller Thermistor
99
Thermostat Control
101
Thermostat Control with Operation Mode Set to AUTO
103
List of Swing Flap Operations
104
Hot Start Control (in Heating Operation Only)
105
Louver Control for Preventing Ceiling Dirt (FCQ Models Only)
106
Drain Pump Control
107
Freeze-Up Prevention
109
Heater Control (Except FTQ-TA Models)
111
Heater Control (FTQ-TA Models)
112
3-Step Thermostat Processing (FTQ-TA Models)
116
Fan Control (Heater Residual) (FTQ-TA Models)
117
Interlocked with External Equipment (FTQ-TA Models)
117
Part 5 Field Settings and Test Operation
119
Field Setting from Remote Controller
120
Wired Remote Controller
120
Simplified Remote Controller
122
Wireless Remote Controller
123
List of Field Settings for Indoor Unit
124
Details of Field Settings for Indoor Unit
128
Operation Control Mode
143
Field Settings from Outdoor Unit
144
Capacity Setting
144
Setting Mode and Monitor Mode
145
Setting Mode 1
146
Setting Mode 2
148
Monitor Mode
152
Setting of Low Noise Operation and Demand Operation
154
Setting of Refrigerant Recovery Mode
157
Setting of Vacuuming Mode
157
Check Operation
158
Setting of Auxiliary Heater Control
159
Setting of Heat Pump Lockout and Emergency Heat Mode
160
Test Operation
162
Check Work Prior to Turning Power Supply on
162
Turn Power on
162
Test Operation
163
Error Codes and Corresponding Measures
166
When Turning on Power First Time
168
When Turning on Power the Second Time and Subsequent
168
When an Indoor Unit or Outdoor Unit Has Been Added, or Indoor or Outdoor Unit PCB Has Been Changed
168
Part 6 Service Diagnosis
169
Servicing Items to be Confirmed
172
Troubleshooting
172
Precautions for Maintenance
172
Refrigerant Properties (R-410A)
174
Symptom-Based Troubleshooting
175
Indoor Unit Overall
175
With Optional Infrared Presence/Floor Sensor
178
Troubleshooting with Remote Controller
180
Wired Remote Controller
180
Wireless Remote Controller
181
Troubleshooting by Error Codes
183
Error Codes and Description
183
Error Codes - Sub Codes
185
Error Code Indication by Outdoor Unit PCB
187
External Protection Device Abnormality (Except FTQ-TA)
191
External Protection Device Abnormality (FTQ-TA Only)
192
Indoor Unit PCB Abnormality
193
Drain Level Control System (S1L) Abnormality
194
Indoor Fan Motor (M1F) Lock, Overload
196
Indoor Fan Motor Abnormality
198
Blower Motor Not Running
202
Indoor Fan Motor Status Abnormality
203
Low Indoor Airflow
204
Swing Flap Motor Abnormality
205
Power Supply Voltage Abnormality
207
Blower Motor Stops for Over/Under Voltage
208
Electronic Expansion Valve Coil Abnormality, Dust Clogging
209
Drain Level above Limit
211
Capacity Determination Device Abnormality
212
Transmission Abnormality (between Indoor Unit PCB and Fan PCB)
213
Blower Motor Communication Error
215
Thermistor Abnormality
216
Combination Abnormality (between Indoor Unit PCB and Fan PCB)
217
Blower Motor HP Mismatch
218
Indoor Blower Does Not Have Required Parameters to Function
219
Remote Sensor Abnormality
220
Infrared Presence/Floor Sensor Error
221
Remote Controller Thermistor Abnormality
226
Outdoor Main PCB Abnormality
227
Activation of High Pressure Switch
228
Activation of Low Pressure Sensor
230
Inverter Compressor Motor Lock
232
Outdoor Fan Motor Abnormality
234
Electronic Expansion Valve Coil Abnormality
236
Discharge Pipe Temperature Abnormality
237
Refrigerant Overcharged
238
Thermistor Abnormality
239
High Pressure Sensor Abnormality
240
Low Pressure Sensor Abnormality
241
PCB (for Inverter Compressor) Abnormality
242
Radiation Fin Temperature Rise Abnormality
243
Inverter Compressor Instantaneous Overcurrent
244
Inverter Compressor Overcurrent
245
Inverter Compressor Startup Abnormality
246
Transmission Error (between Microcomputers on the Outdoor Main PCB)
247
Inverter Circuit Capacitor High Voltage
248
Radiation Fin Thermistor Abnormality
249
Refrigerant Shortage
250
Power Supply Insufficient or Instantaneous Abnormality
252
Check Operation Not Executed
254
Transmission Error between Indoor Units and Outdoor Units
255
Transmission Error between Remote Controller and Indoor Unit
257
Transmission Error between Main and Sub Remote Controllers
258
Transmission Error between Indoor and Outdoor Units in the same System
259
Improper Combination of Indoor and Outdoor Units, Indoor Units and Remote Controller
260
Incorrect Electric Heater Capacity Setting
262
Address Duplication of Centralized Controller
263
Transmission Error between Centralized Controller and Indoor Unit
264
System Not Set
265
System Abnormality, Refrigerant System Address Undefined
266
Check
267
High Pressure Check
267
Low Pressure Check
268
Superheat Operation Check
269
Power Transistor Check
270
Refrigerant Overcharge Check
271
Refrigerant Shortage Check
272
Vacuuming and Dehydration Procedure
273
List of Inverter-Related Error Codes
274
Concept of Inverter-Related Error Codes
275
Thermistor Check
276
Pressure Sensor Check
279
Broken Wire Check of the Relay Wires
280
Fan Motor Connector Check
281
Electronic Expansion Valve Coil Check
283
Fan Motor Connector Check for FTQ-TA
286
Part 7 Appendix
290
Wiring Diagrams
291
Outdoor Unit
291
Indoor Unit
293
Daikin SkyAir RZR48TAVJU Service Manual (291 pages)
Cooling Only 60 Hz Heat Pump 60 Hz
Brand:
Daikin
| Category:
Air Conditioner
| Size: 5.93 MB
Table of Contents
Introduction
7
Part 1 General Information
15
Part 2 Refrigerant Circuit
47
Part 3 Remote Controller
57
Advertisement
Daikin SkyAir RZR48TAVJU Installation Manual (22 pages)
Brand:
Daikin
| Category:
Air Conditioner
| Size: 5.27 MB
Table of Contents
Figures
2
Figure
2
Table of Contents
3
Figure
4
Safety Considerations
5
Introduction
6
Before Installation
7
Figure
7
Selecting Installation Site
7
Standard Operation Limit
7
Standard Supplied Accessories
7
Figure
8
Figure
9
Figure
10
Air Tight Test and Vacuum Drying
11
Figure
11
Thermal Insulation of Piping
11
Electric Wiring
12
Figure
12
Wiring Connection Example for Whole System
12
Figure
13
How to Connect the Power Supply Wiring
13
How to Lay the Power Supply Wiring and Transmission Wiring
13
Adding Refrigerant
14
Additional Refrigerant Charge
14
Before Adding Refrigerant
14
Checking the Refrigerant Tank
14
Figure
14
Transmission Wiring Connection Procedure
14
Post-Work Checks
15
Power On-Check Operation
15
Test Operation
15
Energy Saving and Optimum Operation
16
Final Refrigerant Charge Adjustment
16
Temperature Control Operation Checklist
16
Several Comfort Settings Are Available
17
Three Main Operation Methods Are Available
17
Setting of Heat Pump Lockout and Emergency Heat Mode
19
Caution for Refrigerant Leaks
21
Connecting the Refrigerant Piping
10
Installation Tools
10
Pipe Connection
10
Protection against Contamination When Installing Pipes
10
Refrigerant Piping
10
Selecting Piping Material
10
Precautions on Installation
9
Daikin SkyAir RZR48TAVJU Installation Instructions Manual (16 pages)
SNOW HOOD and SNOW VISOR
Brand:
Daikin
| Category:
Heat Pump
| Size: 2.85 MB
Table of Contents
Table of Contents
1
Special Considerations before Snow Hood Installation
5
Single/Double Fan Snow Visor Installation
6
Single/Double Fan Front Snow Hood Installation
7
Single/Double Fan Rear Snow Hood Installation
10
Single/Double Fan Side Snow Hood Installation
12
Advertisement
Related Products
Daikin RZR48HUY2S
Daikin RZR48KUV2S
Daikin SkyAir RZR48TAVJUA
Daikin RZR48MUYMK
Daikin RZR48TBVJUA
Daikin RZR42PVJU
Daikin RZR42KUV2S
Daikin SkyAir RZR42TAVJU
Daikin SkyAir RZR42TAVJUA
Daikin RZR42PVJU8
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals