Sign In
Upload
Manuals
Brands
Carrier Manuals
Controller
TruVu VAVB3-E2
Carrier TruVu VAVB3-E2 Manuals
Manuals and User Guides for Carrier TruVu VAVB3-E2. We have
1
Carrier TruVu VAVB3-E2 manual available for free PDF download: Installation And Startup Manual
Carrier TruVu VAVB3-E2 Installation And Startup Manual (155 pages)
Brand:
Carrier
| Category:
Controller
| Size: 4.71 MB
Table of Contents
Table of Contents
3
What Is the TV-VAVB3-E2
7
Specifications
10
Linkage
14
Safety Considerations
15
Zone Sensors
16
Touchscreen Devices
16
Field-Supplied Hardware
17
To Mount the TV-VAVB3-E2
18
Wiring for Power
20
To Remove the TV-VAVB3-E2'S Cover
20
To Wire for Power
21
Addressing the TV-VAVB3-E2 through the Comm/Service Ports
22
To Set the IP Address
24
Addressing a Network of Controllers Using the Controller Setup Local Network Tab
25
Method 1: to Address When You Know the Serial Numbers
25
Method 2: to Address When You Do Not Know the Serial Numbers
26
Wiring for Communications
28
Wiring Devices to the TV-VAVB3-E2'S Rnet Port
29
Wiring Devices to the TV-VAVB3-E2'S Act Net Port
30
Wiring Inputs and Outputs
31
Inputs
31
Outputs
31
Wiring Specifications
32
To Wire Inputs and Outputs
33
To Adjust Input and Output Properties
36
Input Values
37
Output Values
38
Resolution Values
38
Offset/Polarity Values
39
Wiring Sensors to the TV-VAVB3-E2'S Inputs
40
Wiring Specifications
40
To Wire the T55 Sensor to the Controller
41
To Wire the Supply Air Temperature Sensor to the Controller
41
To Wire the CO2 Sensor to the Controller
42
To Wire the Relative Humidity Sensor to the Controller
44
Wiring a Remote Occupancy Sensor
45
Using the Airflow Sensor
46
To Connect Duct Tubes to the Airflow Sensor
46
To Set up the Airflow Control Microblock
47
Wiring Equipment to the TV-VAVB3-E2'S Outputs
48
Wiring Specifications
48
Wiring Diagram Legend
48
No Heat - Single Duct or Fan Box Application
49
2-Position Hot Water/Steam Heat - Single Duct
50
Modulating Hot Water/Steam (Ducted or Baseboard) - Single Duct Application
51
Combination Heat (Ducted Electric Heat with Modulating Baseboard Heat) - Single Duct Application
52
Electric Heat (Ducted or Baseboard) - Single Duct Application
53
SCR Electric Heat (Ducted or Baseboard) - Single Duct Application
54
2-Position Hot Water/Steam (Ducted or Baseboard) - Fan Box Application
55
Modulating Hot Water (Ducted or Baseboard) - Fan Box Application
56
Combination Heat (Ducted Electric Heat with Modulating Baseboard Heat) - Fan Box Application
57
2-Stage Electric Heat (Ducted or Baseboard) - Fan Box Application
58
SCR Electric Heat (Ducted or Baseboard) - Fan Box Application
59
Wiring a Field-Supplied High-Torque Actuator to the Analog Output
60
Start-Up
61
Configuring the TV-VAVB3-E2'S Properties
61
Configuring ZS Sensors
62
Performing System Checkout
62
Commissioning the TV-VAVB3-E2
63
Balancing the System Using the I-Vu®/Field Assistant Applications
63
Prepare for Balancing
64
Balance each Zone
64
Balancing the System Using Test & Balance Tool
65
To Calibrate VAV Zone Airflow
65
Upload Calibration Values to the I-Vu® Application
66
Run a Report in TV-VAVB3-E2 (Optional)
67
Balancing the System
67
Prepare for Balancing
67
Sequence of Operation
67
Temperature Sensors
68
Zone Airflow Control
68
Zone Reheat Control
69
Demand Control Ventilation (DCV) and Dehumidification Using Optional Sensors
71
Occupancy
72
Alarms
73
Demand Limiting
74
Linkage
74
Linkage Modes and Determination
77
Zone Environmental Index
79
Find and Upload in the I-Vu® Interface
80
Adjusting the TV-VAVB3-E2 Driver Properties
81
Driver
81
Device
83
Notification Classes
83
Calendars
84
Common Alarms
85
Specific Events
85
Custom Translation Tables
86
Bacnet Controller Properties
86
Bacnet Firewall
87
Network Diagnostics - Statistics
88
Network Diagnostics - Packet Capture
89
Act Net Bus
90
Communication Status
92
Flow Calibration Archive
92
To Set up Network Statistic Trends
93
To Set up the Controller through the Comm/Service Ports
94
Modstat Tab
94
Device Tab
95
Ports Tab
95
Bacnet Tab
96
Security Tab
96
Local Network Tab
96
To Communicate through the Bacnet/Service Port Network
100
Wiring Specifications
101
To Communicate Locally through the Rnet Port
102
To Set up a Local Access Connection in the I-Vu® Interface
103
Troubleshooting
104
Leds
104
To Use the Locator LED
106
To Configure Custom Prog 1/2 Leds
107
To Get a Module Status Report
107
Troubleshooting Inputs and Outputs
108
To Get a Device Log
109
To Get the TV-VAVB3-E2'S Serial Number
110
To Take the TV-VAVB3-E2 out of Service
110
To Replace the TV-VAVB3-E2'S Fuse
111
To Revert to Default Settings
111
Compliance
112
FCC Compliance
112
CE Compliance
112
Industry Canada Compliance
112
Bacnet Compliance
112
Appendix A: TV-VAVB3-E2 Points/Properties
113
Status
113
Unit Configuration
114
Setpoints
117
Alarm Configuration
124
Service Configuration
126
Maintenance
134
Alarms
138
Linkage
139
I/O Points
141
Appendix B: VAV Terminal Modes
145
Appendix C: ZS Sensor Display for TV-VAVB3-E2
147
Appendix D: Bacnet Points List
148
Appendix E: Module Status Field Descriptions
151
Document Revision History
153
Advertisement
Advertisement
Related Products
Carrier VAV Zone II
Carrier VAV Zone II Secondary Duct
Carrier VVT Zone
Carrier VVT Zone II
Carrier VVT 33ZC
Carrier VVT Bypass II
Carrier RTU Open v5
Carrier TruVu VVTZC-E2
Carrier TruVu VVTBP-E2
Carrier VVT Bypass
Carrier Categories
Air Conditioner
Heat Pump
Furnace
Thermostat
Chiller
More Carrier Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL