Sign In
Upload
Manuals
Brands
ADT Manuals
Control Panel
Unimode 9600
ADT Unimode 9600 Manuals
Manuals and User Guides for ADT Unimode 9600. We have
1
ADT Unimode 9600 manual available for free PDF download: Installation And Operating Instruction
ADT Unimode 9600 Installation And Operating Instruction (148 pages)
ADT Addressable Fire Alarm Control Panel Programming, Installation, Maintenance and Operating Instruction Manual
Brand:
ADT
| Category:
Control Panel
| Size: 2 MB
Table of Contents
Fire Alarm System Limitations
2
FCC Warning
3
Installation Precautions
3
Table of Contents
5
SECTION 1: Product Description
12
Inventory
12
Features and Options
12
Specifications
14
1: Current Availability
15
Controls and Indicators
16
Circuits
17
Components
17
1: Intelligent Addressable Detectors: Newer Series
18
2: Intelligent Addressable Modules: Newer Series
19
3: 300 Series Intelligent Addressable Devices
20
4: Addressable Device Accessories
20
Optional Modules
20
Accessories
21
1: PK-9600 Programming Utility
21
2: Dress Panel
21
3: Battery Box
21
4: ADT-CHG-120 Battery Charger
22
5: Annunciators
22
Getting Started
23
SECTION 2: Installation
24
Mounting
24
Power
27
1: AC Power and Earth Ground Connection
27
2: Battery Power
27
3: DC Power Output Connection
27
Relays
28
Notification Appliance Circuits
28
UL Power-Limited Wiring Requirements
29
Optional Modules and Devices
30
1: 4XTMF Transmitter Module Installation
31
2: Auxiliary Trouble Input (J16 & J17)
32
3: SLC-2 Expander Module
33
4: Printer/Pc
34
5: Digital Communicator and Annunciators
35
ADT-UDACT Digital Alarm Communicator/Transmitter
35
ADT-ACM-8R Relay Control Module
35
BRKT-9600 Universal Bracket Installation
35
ADT-ACS and ADT-AFM Series Annunciators
37
SECTION 3: Programming
38
Programming Data Entry
38
User Programming
39
Initial Power-Up
40
Programming Screens Description
40
Programming and Passwords
40
Master Programming Level
42
1: Point Program
43
Detector Programming
43
Add Detector
43
Delete Detector
44
Edit Detector
44
Zone@Assignment
49
Module Programming
53
Add Module
53
Delete Module
54
Edit Module Screen for Monitor Module
54
Edit Module Screen for Control Modules
63
2=Zone Setup
70
Enable
70
Disable
71
Zone 97, 98 and 99
71
Zones Installed
72
Zones Enabled
72
Zones Disabled
72
Zone Type
73
3=Loop Setup
74
Style
74
Loop Protocol
74
4: System Setup
75
Trouble Reminder
75
Banner
76
Time-Date
77
Time
77
Date
78
Clock Format
78
Daylight Savings Time
78
Timers
79
PAS (Positive Alarm Sequence) Delay
79
Presignal@Delay
80
Waterflow Delay
80
AC Loss Delay
81
NAC (Notification Appliance Circuit)
81
Enabled
82
Type
83
Silenceable
83
Auto Silence
84
Coding
84
Zone
85
Silence Inhibited
85
Synced Type
85
Relays
86
5: Autoprogram
87
6: Verify Loops
88
7: History
88
View Events
89
Erase History
89
8: Walktest
90
9: Option Modules
91
Annunciators/Udact
91
Printer/Pc
92
10: Password Change
93
11: Clear Program
94
12: Program Check
95
Maintenance Programming Level
97
1: Disable Point
98
2=History
99
3=Program Check
100
4: Walktest
101
5: System
101
6: Zone Setup
103
SECTION 4: Operating Instructions
105
Panel Control Buttons
105
1: Acknowledge/Step
105
2: Alarm Silence
105
3: Drill/Hold 2 Sec
105
4: Reset
105
LED Indicators
106
Normal Operation
107
Trouble Operation
107
Alarm Operation
109
Supervisory Operation
110
Process Monitor Operation
111
Hazard Condition Operation
111
Medical Alert Condition Operation
111
NAC Operation
111
Programmed Zone Operation
112
Disable/Enable Operation
112
Waterflow Circuits Operation
112
Detector Functions
112
Time Functions: Real-Time Clock
112
Synchronized NAC Operation
113
Coded Operation
113
Presignal
113
Positive Alarm Sequence
114
Special System Timers
115
1: Silence Inhibit Timer
115
2: Autosilence Timer
115
3: Trouble Reminder
115
4: Waterflow Retard Timer
115
5: Alarm Verification (None or Two Minutes)
116
Walktest
116
Read Status
117
1: System Point
118
3=Power
118
2=Zones
119
4: Trouble Reminder
120
5: Timers
121
6: Nac
121
7: Relays
122
8: Program Check
122
9: History
122
10: Annunciators
123
11: Printer/Pc
123
12: Print
124
13: Time-Date
126
SECTION 5: Power Supply Calculations
127
Overview
127
Calculating the AC Branch Circuit
127
Calculating the System Current Draw
128
1: Overview
128
2: How to Use Table 5.3 on Page 129 to Calculate System Current Draw
128
NFPA Battery Requirements
130
Selecting and Locating Batteries
130
Calculating the Battery Size
130
A.1: Correlations
131
Advertisement
Advertisement
Related Products
ADT Unimode 400 Multi-Net
ADT Unimode 400 Multi-Net Analog Fire Panel
ADT 967
ADT 927
ADT ADT-LCD40
ADT ADT-LCD40L
ADT Categories
Security System
Control Panel
Security Sensors
Security Camera
DVR
More ADT Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL