SERVICE JIGS
The following jigs (extension cable kit) are used when repairing the PCBs.
Order the jigs from your dealer if necessary.
CAUTION : Incorrect connections may cause malfunction.
•
Connection of Jig for DIGITAL PCB
-Items to Be Prepared-
8U- 110084S
:
Insulation sheet (Not supplied)
Ground lead (Not supplied)
-Procedures-
(1) Remove the screws.
(2) Remove the connector PCB. Remove the screws.
(3) Remove the DIGITAL PCB from the chassis and turn it over.
Place an insulation sheet larger than the PCB underneath the DIGITAL PCB.
Connect the earth of the PCB to the chassis using an earth wire, etc.
b
PCB DIGITAL
Insulation sheet
CHASSIS-COMPOSIT CONNECTOR
EXTENSION UNIT KIT
:
1sheet
:
2 pc
CN8221
:
1 Set
Front side
CHASSIS-HDMI CONNECTOR