Page 1
Owner’s Manual Keep with machine for reference MODEL L-1C Installation & Operations Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T A V E N U E...
ABLE OF ONTENTS CMA-L-1C ODEL 1. SPECIFICATIONS ..................2 1.1. L-1C ..............................2 1.2. L-1C O ......................3 PERATIONAL YCLE 2. GETTING STARTED ..................5 2.1. L-1C......................5 NTRODUCTION TO THE 2.2....................... 6 ECEIVING AND NSTALLATION 2.2.1. Electrical ..........................6 2.2.2.
65 PSIG are present, a pressure regulating valve must be installed in the water line to the dishwasher (by others). If flowing pressure is lower than 15 psi, improper machine operation may result. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
1.2. L-1C Operational Cycle The L-1C Operational Cycle has a total cycle time of 2 minutes (120 seconds). The Timing Diagram and the steps listed below detail the individual functions that are executed during each Operational Cycle. Seconds: Instant Start Relay...
Page 5
7. Cam switch 8 operates the optional sustainer heater. This cam assures that the sustainer heater only turns on when the dishmachine is not in a cycle. This prevents the machine from drawing too much electrical current at any one time. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
The supply water to the L-1C must be a minimum of 140°F. The pipe supplying the water must be ½” minimum. The plumbing connection is located at the back of the glasswasher. The drain is a 1" barbed fitting located at the back of the glasswasher for easy attachment of your drain hose.
Prior to installation make sure the electrical supply is compatible with the specifications on the machines data plate A 15-amp, 115 volt, 60 Hz dedicated circuit must be used to supply electrical power to the L-1C Glasswasher (see specification sheet page 1).
Federal, State, and Local Health, Electrical, Plumbing and Safety codes The de-liming agents used to de-scale a commercial dishwasher, are highly caustic and de-liming must be done by a qualified chemical specialist. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
The chemicals and water level must be programmed by a qualified chemical specialist. The de-liming agents are highly caustic and de-liming must be done by qualified chemical specialist. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
Cam 4 can be adjusted to increase the amount of water that is automatically fed into the machine during a cycle (see section 4.1.1 Cam Adjustment). Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
5. Adjust the trailing edge of the cam groove by rotating the appropriate side of the cam in the proper direction to either increase or decrease the cam’s groove; resulting in increasing or decreasing the total time that switch will be held ON. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
NORMAL Delimer switch in wrong position Switch to position Sanitizer pump does not run Faulty 5th micro switch Replace switch, P/N 00411.00 Faulty sanitizer pump motor Replace motor, P/N 00416.00 Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
Defective fill/start switch (cycle Replace fill/start switch start switch does not begin light will not light either) P/N: 03470.01 cycle Replace timer assembly* Defective timer assembly (Cam 1) P/N: 00408.80 Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
Page 14
P/N: 03470.00 Defective sani pump motor Replace pump motor P/N: 00416.00 Activating rinse primer Defective rinse primer switch Replace primer switch switch does not run pump P/N: 03470.00 Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
Page 15
P/N: 00201.00 *The timer assembly motor ( ) or micro switches ( ) can be replaced P/N: 00501.00 P/N: 00411.00 independently if that is the only component that has failed. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...
1. All low energy models must have low level sani-alarms, both visual and audio. 2. All models must have a City of Chicago approval data label affixed to the glasswasher. 3. Chlorine sanitizer must be a minimum of 100 PPM. Page MODEL L-1C INSTALLATION & OPERATION MANUAL Rev. 1.00 A...