Disable Secondary Interface
USB PC or Macintosh Keyboard
Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard. Scanning
these codes also adds a CR and LF for Voyager 1200g and adds CR for Voyager 1202g and 1202g-BF.
USB Keyboard (Mac)
USB Japanese Keyboard (PC)
USB HID
Scan the following code to program the scanner for USB HID bar code scanner.
USB HID Bar Code Scanner
HID Fallback Mode
If you attempt to set a USB interface for your scanner, but the setup fails on the host system, you can program the scanner
to fall back to a USB Keyboard (PC) interface after a set length of time. For example, if the scanner is configured for Serial
Emulation Mode, but the host system does not have the correct driver, the scanner would fail. If you set the HID Fallback
Mode for a set length of time, for example, 5 minutes, the scanner would change to a USB Keyboard (PC) interface after 5
minutes of trying to configure as serial emulation.
A unique beep sequence (Voyager 1200g) or the blinking LEDs on the base (Voyager 1202g/1202g-BF) indicate that this
mode has been entered. While in HID Fallback Mode, the scanner will not scan normal bar codes and sounds a unique
beep sequence (Voyager 1200g) or the base LEDs will blink (Voyager 1202g/1202g-BF) to indicate the scanner is in Fall-
back Mode. Menu codes can still be scanned while in HID Fallback Mode, allowing you to change the scanner's program-
ming.
Scan the bar code below, then set the length for the HID Fallback (from 0-60 minutes) by scanning digits from the
Programming
Chart, then scanning Save. Default = 5 minutes.
HID Fallback Mode
2 - 4